Printed in U.S.A. © 2013  Innovative Hearth Products

P/N 900199-00, Rev. B  10/2016

Innovative Hearth Products
150

8

 Elm Hill Pike, Suite 10

8

 • Nashville, TN 37210

Innovative Hearth Products

Astria

®

 Brand Gas Fireplace

Limited Lifetime Warranty

THE WARRANTY

Innovative Hearth Products ("IHP") Limited Lifetime Warranty warrants your Astria

®

 brand gas fi replace ("Product") to be free from defects in materials and workmanship 

at the time of manufacture. The product body, fi rebox and barrier carry the Limited Lifetime Warranty. Ceramic glass carries the Limited Lifetime Warranty against thermal 
breakage only. After installation, if covered components manufactured by IHP are found to be defective in materials or workmanship during the Limited Lifetime Warranty 
period and while the Product remains at the site of the original installation, IHP will, at its option, repair or replace the covered components. If repair or replacement is not 
commercially practical, IHP will, at its option, refund the purchase price or wholesale price of the IHP product, whichever is applicable. IHP will also pay IHP prevailing labor 
rates, as determined in its sole discretion, incurred in repairing or replacing such components for up to fi ve years. THERE ARE EXCLUSIONS AND LIMITATIONS to this 
Limited Lifetime Warranty as described herein.

COVERAGE COMMENCEMENT  DATE

Warranty coverage begins on the date of purchase.  In the case of new home construction, warranty coverage begins on the date of fi rst occupancy of the dwelling or six 
months after the sale of the Product by an independent IHP dealer/distributor,  whichever occurs earlier.  The warranty shall commence no later than 24 months following 
the date of product shipment from IHP, regardless of the installation or occupancy date.

EXCLUSIONS AND LIMITATIONS

This Limited Lifetime Warranty applies only if the Product is installed in the United States or Canada and only if operated and maintained in accordance with the printed 
instructions accompanying the Product and in compliance with all applicable installation and building codes and good trade practices.

This warranty is non-transferable and extends to the original owner only. The Product must be purchased through a listed supplier of IHP and proof of purchase must be 
provided.  The product body, fi rebox and barrier carry the Limited Lifetime Warranty from the date of installation. Vent components, trim components and paint are excluded 
from this Limited Lifetime Warranty.  The following do not carry the Limited Lifetime Warranty but are warranted as follows:

Burner

 – Repair or replacement for fi ve years from the date of installation

Gas components & electrical components

 – Repair or replacement for one year from the date of installation

Gaskets

 – Repair or replacement for one year from the date of installation

Gold & nickel plating

 - Replacement for two years from date of installation. Excludes tarnishing 

Labor coverage

 – Prevailing IHP labor rates apply for the warranty period of the component 

Light bulbs & batteries

 – Replacement for 90 days from the date of installation

Logs

 – Replacement for fi ve years from the date of installation against thermal breakage only

Optional blowers & remote controls

 – Repair or replacement for one year from the date of installation

Optional glass doors & optional glass accessories 

– Repair or replacement for 90 days from the date of installation

Optional surrounds

 – Stone/Natural Materials: Replacement for one year against cracking or breakage due to thermal stress. Other Materials: Replacement for one 

year. Excludes surface and hairline cracks and scratches or slight color changes that do not affect the operation or safety of the unit

Tempered Glass

 -Replacement for one year from the date of installation

Parts not otherwise listed carry a 90 day warranty from the date of installation.

Whenever practicable, IHP will provide replacement parts, if available, for a period of 10 years from the last date of manufacture of the Product.

IHP will not be responsible for: (a) damages caused by normal wear and tear, accident, riot, fi re, fl ood or acts of God; (b) damages caused by abuse, negligence, misuse, or 
unauthorized alteration or repair of the Product affecting its stability or performance (The Product must be subjected to normal use. The Product is designed to burn either 
natural or propane gas only. Burning conventional fuels such as wood, coal or any other solid fuel will cause damage to the Product, will produce excessive temperatures 
and could result in a fi re hazard.); (c) damages caused by failing to provide proper maintenance and service in accordance with the instructions provided with the Product; 
(d) damages, repairs or ineffi ciency resulting from faulty installation or application of the Product.

IHP is not responsible for inadequate fi replace system draft caused by air conditioning and heating systems, mechanical ventilation systems, or general construction conditions 
which may generate negative pressure in the room in which the appliance is installed.  Additionally IHP assumes no responsibility for drafting conditions caused by venting 
confi gurations, adjoining trees or buildings, adverse wind conditions or unusual environmental factors and conditions that affect the operation of the unit.

This Limited Lifetime Warranty covers only parts and labor as provided herein. In no case shall IHP be responsible for materials, components or construction,  which are not 
manufactured or supplied by IHP or for the labor necessary to install, repair or remove such materials, components or construction. Additional utility bills incurred due to 
any malfunction or defect in equipment are not covered by this warranty. All replacement or repair components will be shipped F.O.B. from  the nearest stocking  IHP factory.

LIMITATION ON LIABILITY

It is expressly agreed and understood that IHP’s sole obligation and the purchaser’s exclusive remedy under this warranty, under any other warranty, expressed or implied, 
or in contract, tort or otherwise, shall be limited to replacement, repair, or refund, as specifi ed herein.

In no event shall IHP be liable for any incidental or consequential damages caused by defects in the Product, whether such damage occurs or is discovered before or after 
repair or replacement, and whether such damage is caused by IHP’s negligence. IHP has not made and does not make any representation or warranty of fi tness for a particular 
use or purpose, and there is no implied condition of fi tness for a particular use or purpose.

IHP makes no expressed warranties except as stated in this Limited Lifetime Warranty. The duration of any implied warranty is limited to the duration of this expressed warranty. 

No one is authorized to change this Limited Lifetime Warranty or to create for IHP any other obligation or liability in connection with the Product. Some states and provinces 
do not allow the exclusion or limitation of incidental or consequential damages, so the above limitations or exclusions may not apply to you. The provisions of this Limited 
Lifetime Warranty are in addition to and not a modifi cation  of or subtraction from any statutory warranties and other rights and remedies provided by law.

INVESTIGATION OF CLAIMS AGAINST WARRANTY

IHP reserves the right to investigate any and all claims against this Limited Lifetime Warranty and to decide, in its sole discretion, upon the method of settlement.

To receive the benefi ts and advantages described in this Limited Lifetime Warranty, the appliance must be installed and repaired by a licensed contractor approved by IHP. 

Contact IHP at the address provided herein to obtain a listing of approved dealers/distributors. 

IHP shall in no event be responsible for any warranty work done by a 

contractor that is not approved without fi rst obtaining IHP's prior written consent.

HOW TO REGISTER A CLAIM AGAINST WARRANTY

In order for any claim under this warranty to be valid, you must contact the IHP dealer/distributor from which you purchased the product. If you cannot locate the dealer/
distributor, then you must notify IHP in writing. IHP must be notifi ed of the claimed defect in writing within 90 days of the date of failure. Notices should be directed to the 
IHP Warranty Department at 1508 Elm Hill Pike, Suite 108, Nashville, TN 37210 or visit our website at WWW.ASTRIA.US.COM.

Summary of Contents for Marin 40STTMN

Page 1: ...appareil ou de tout autre appareil QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ Ne pas tenter d allumer d appareil Netouchez aucaninterrupteur Nepasvousservir des t l phones se trouvant dans le b timent...

Page 2: ...ITRE EL VIDRIO CALIENTE CAUSAR QUEMADURAS USTED DEBE NUNCA TOCAR EL VIDRIO CALIENTE LOS NI OS DEBEN NUNCA TOCAR EL VIDRIO L cran pare tincelles fourni avec ce foyer r duit le risque de br lure en cas...

Page 3: ...uncionamiento Supervise en forma cercana a los ni os en cualquier cuarto donde haya una chimenea funcionando para impedir el contacto con el vidrio Mantenga la ropa mobiliario gasolina y otros l quido...

Page 4: ...e barrier becomes dam aged the barrier shall be re placedwiththemanufacturer s barrier for this appliance For use with barrier s Part No s J7420 INTRODUCTION The Millivolt appliances have a millivolt...

Page 5: ...TheInstallationmustconformtolocalcodesor in the absence of local codes with the National Fuel Gas Code ANSI Z223 1 NFPA 54 latest edition InCanada thecurrentCAN CGA B149 1 installation code The appli...

Page 6: ...ude THE CONVERSION SHALL BE CAR RIED OUT BY A MANUFACTURER S AUTHO RIZED REPRESENTATIVE IN ACCORDANCE WITH THE REQUIREMENTS OF THE MANU FACTURER PROVINCIAL OR TERRITORIAL AUTHORITIES HAVING JURISDICTI...

Page 7: ...so important Due to high temperatures the appliance should be located out of traffic and away from furniture and draperies Figure 2 En raison des temp ratures lev es l appareildevrait treinstall dansu...

Page 8: ...y from the roof surface National Fuel Gas Code ANSI Z223 1 NFPA 54 CAN CGA B149 1 Multiple Terminations These appliances may vent adjacent to and at the same level with any other gas appliances includ...

Page 9: ...ee Figure 5 Mantels constructed of non combustible materials may be installed at any height above the appliance opening however donotallowanythingtohangbelowthefireplacehood Minimumclearancerequiremen...

Page 10: ...or detailed procedures Step 1 Page 11 Construct the appliance framing Position the appliance within the framing and secure with nailing brackets and floor anchor tabs Step 2 Page 13 Route gas supply l...

Page 11: ...nailing flanges Install the 8 nailing flanges as shown in Figure 8 using the existing screws Position the fireplace within the framing When required theflangesmaybebent90degreesby hand or with the ass...

Page 12: ...19 41 1 8 1045 37 3 4 959 40 1 4 1022 41 1041 37 940 34 1 8 867 23 1 2 597 27 3 4 705 23 7 8 607 41 1041 2 51 FRAMING SPACERS Top and both sides FINISHED WALL BRACKET Front and back edge of unit top S...

Page 13: ...mpounds are used in propane applications Be very careful that the pipe compound does not get inside the pipe It is recommended to install a sediment trap in the supply line as close as possible to the...

Page 14: ...both models A Millivolt Wiring See Figure 14 Install Optional Control Switch OFF ON wall switch or remote control receiver Install snap bushing onbrownwallswitchwire intocontrol switch knock out in s...

Page 15: ...o the left away from the fireplace The lower control compartment door on the side opposite the valve lifts on and off The millivolt control valve has a 3 8 10mm NPT thread inlet port Secure all joints...

Page 16: ...loor Joists and under the home to a ventilated crawlspace not considered part of the living area of the home NOTE Do not terminate outside air kit in attic space under any circumstances CAUTION NEVER...

Page 17: ...any ports are blocked or partially blocked clean out the ports With gas line installed run initial system checkout before closing up the front of the unit Follow the pilot lighting instructions provi...

Page 18: ...volcanic stone evenly over firebox floor 6 Install Vermiculite Place some vermiculite on the firebox floor around thegrate theentirebagofvermiculitewillNOTbeused DONOTPLACE ANY VERMICULITE ON THE BUR...

Page 19: ...nst The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bottom Of Log 2 Over The Grate Here And Slide It Against The Back Of The Gra...

Page 20: ...The Grate Rest Log 5 Against The Grate Here Log 5 Sits In Front Of The Grate STEP 5 NOTICE Marin40ST model fireplac es include barriers to reduce the risk of burns from hot viewing glass The barriers...

Page 21: ...ring that the gasket seats evenly as the door frame draws shut Fasten the latch located underneath the firebox floor to the door s vee flange Close the latch securely NOTE Front Face Assembly with bar...

Page 22: ...lation and Page 9 for Clearances Figure 27 Finishing Requirements This Area Must Remain Clear of Combustible Materials Top of Appliance 1 Min 25 mm Combustible Wall Framing Spacer Top of Door Frame Ho...

Page 23: ...y of the burner on off wall switch it may be due to the operation of this safety limit switch First allow the appli ance to cool then reset the safety switch by pushing the red reset button on the bac...

Page 24: ...une t l commande est utilis e pour contr ler le foyer nettoyez la soigneusement pour liminer la poussi re et les traces de graisse ou d huile Collez l tiquette sur le bo tier de la t l commande Figure...

Page 25: ...r s left side to the right until it disengages from the left corner post hole Pull the door diagonally to the left away from the fireplace Remove the modesty panel by pulling the bottomrightcornerofth...

Page 26: ...ter to the manifold side pressure test fitting and verify manifold pressure reads 3 5 water column 0 87 kPa for natural gas and 10 0 water column 2 49 kPa for propane gas Step 6 Refer to Figure 31 and...

Page 27: ...2 todisengage and swing the panel open from top On millivolt systems the piezo igniter Hi Lo flame adjustment knob and pilot and main gas ON OFF control knob are located on the modesty panel The gas...

Page 28: ...nfants ou les adultes peuvent subir des br lures s ils viennent en contact avec la surface chaude Il est recommand d installer une barri re physique si des personnes risques habitent la maison Pour em...

Page 29: ...tiquette sur la surface de la plaque de l interrupteur mural quicontr lelefoyer FigureA Choisissezlalangue qui est principalement parl e dans la r sidence du propri taire 2 Si une t l commande est ut...

Page 30: ...gas indicated on rating plate This appliance is not convertible for use with other gases unless a certified kit is used These appliances are designed to oper ate on natural gas or propane gas only The...

Page 31: ...ng thefirsttwoweeksofusetopreventthefilmfrom baking on making it very difficult to remove See Cleaning Glass on Page 34 Orifice Sizes Sea Level to High Altitude All Models These appliances are tested...

Page 32: ...ressure Port Main Gas Control Knob IN OUT SIT Millivolt Gas Valve Outside Combustion Air Controls Manyappliancesareequipped wheninstalled with an outside make up air vent system that is designed to pr...

Page 33: ...ly of the burner on off wall switch it may be due to the operationofthissafetylimitswitch Firstallow the appliance to cool then reset the safety switch by pushing the red reset button on it A To acces...

Page 34: ...before initial use and at least annually by a qualified service technician inspectionshouldincludeensuringthatventing system is unobstructed and vent components are properly assembled and not damaged...

Page 35: ...closure Panel see Figure 38 Retrieve the glass door Visually inspect the gasket on the backside of the frame Gasket surface must be clean free of irregularities and seated firmly Position the door in...

Page 36: ...evenly over firebox floor 6 Install Vermiculite Place some vermiculite on the firebox floor around the grate the entire bag of vermiculite will NOT be used DO NOT PLACE ANY VERMICULITE ON THE BURNER N...

Page 37: ...The Grate Here Position Log 2 Over The Grate Bar And Slide It Against The Back Of The Grate Here Position Groove At The Bottom Of Log 2 Over The Grate Here And Slide It Against The Back Of The Grate P...

Page 38: ...2 3 Grate Assembly 5 Position Small End Of Log 6 On The Notch Of Log 3 Here 6 4 Position The Round End Of Log 6 Against The Notch Of Log 4 Here Two Charred Spots Face The Front Position The Groove In...

Page 39: ...shutter opening must be adjusted between these two extremes Air Shutter Adjustment Guidelines Amount of Primary Air Flame Color Air Shutter Adjustment If air shutter is closed too far Flame will be o...

Page 40: ...ng conditions are present adjust accordingly If flame appears weak or sooty adjust the air shutter incrementally to a more open position until the proper flame appearance is achieved If flame remains...

Page 41: ...___________________ Parts will be shipped at prevailing prices at time of order When ordering repair parts always give the following information 1 The model number of the appliance 2 The serial number...

Page 42: ...Volcanic Stone Bag of Vermiculite Replacement ember materials volcanic stone or vermiculite are available for use with these appli ances Order kits as part of the periodic maintenance of the applianc...

Page 43: ...Remote Two Button Timer On Off Or Timer Mode Cat No Model No Description H8860 RC S 1 Remote Control Cost Effective Solution Simple On Off operation Kit includes Remote and Receiver Manual or up to 3...

Page 44: ...d by long lateral runs too many elbows and or exterior portions of the systembeingexposedtocoldweather Alsoinspectwallstraps or plumbers s tape to ensure it is secure and in place Appliance Checkout Q...

Page 45: ...AND IMMEDIATELY CALL your service technician or gas supplier LIGHTING INSTRUCTIONS TO TURN OFF GAS TO APPLIANCE s F THE PILOT WILL NOT STAY LIT AFTER SEVERAL TRIES TURN THE GAS CONTROL knob to OFF and...

Page 46: ...LA VEILLEUSE NE RESTE PAS ALLUM E APR S PLUSIEURS TENTATIVES r glez la manette d admission du gaz la position OFF et appelez un technicien qualifi ou le fournisseur de gaz 10 Tournez le bouton de r g...

Page 47: ...ot flame it must impinge on thermocouple see Figure 45 on Page 40 Clean and or adjust pilot for maximum flame impingement on thermocouple Ensure that the connection between the valve and thermocouple...

Page 48: ...ty 1 Hood Black 40 J7536 2 2 Glass Enclosure Assembly 40 H6365 2 3 Log Set 55M04 1 4 Bag of Vermiculite H6319 1 5 Bag of Embers rockwool 88L53 1 6 Bag of Decorative Volcanic Stone 80L42 1 7 Burner Ass...

Page 49: ...2017 Innovative Hearth Products Marin See Through B Vent Gas Fireplaces NOTE See the tables on Page 48 for replacement parts applicables REPLACEMENT PARTS Cat No Model F0869 Marin 40STMN 3 2 14 5 6 4...

Page 50: ...______ _____________________________________________________ _____________________________________________________ _____________________________________________________ _______________________________...

Page 51: ...t re ood or acts of God b damages caused by abuse negligence misuse or unauthorized alteration or repair of the Product affecting its stability or performance The Product must be subjected to normal u...

Page 52: ...rices and also to discon tinue colors styles and products Consult your local distributor for fireplace code information Printed in U S A 2015 Innovative Hearth Products P N 900301 01 Rev D 04 2017 150...

Reviews: