![Astria Fireplaces Marin 40STTMN Assembly, Installation And Operation Instructions Download Page 32](http://html1.mh-extra.com/html/astria-fireplaces/marin-40sttmn/marin-40sttmn_assembly-installation-and-operation-instructions_2990900032.webp)
32
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Operation
900301-01 04/2017
Innovative Hearth Products
Marin™ See-Through B-Vent Gas Fireplaces
Figure 35
NOTE: The piezo igniter is located on the modesty panel - refer to Figure 34.
Variable Flame Height Adjustment
( Millivolt Appliances only)
All Millivolt appliances are equipped with a variable gas control valve. Flame height for these
models may be adjusted through a range between fi xed low and high settings, alternately, while
the appliance is in operation.
Adjust the fl ame height as desired after lighting the appliance by rotating the variable adjustment
control knob located on the front of the valve
(refer to Figure 35)
.
(An extension is provided to
this knob so that the adjustment may be made at the modesty panel).
HI
LO W
TPTH
TP
TH
PILO
T
PIL
O
T
ON
i
t
OFF
Variable Flame Height Adjustment
Manifold Pressure Port
Inlet Pressure Port
Main Gas
Control Knob
IN
OUT
SIT Millivolt Gas Valve
Outside Combustion Air Controls
Many appliances are equipped, when installed,
with an outside (make-up air) vent system
that is designed to provide the appliance with
outside make-up air for combustion when in
operation. The outside air control lever for the
outside air system is standard on all appliances
but should not be operated if the complete
system is not installed. Refer to
Figure 36
.
When the complete outside air vent system is
installed, the installer will remove the securing
screw from the combustion air control lever
located on the right side of the fi replace opening.
If the securing screw has not been removed
and you have reason to believe that you have
a complete outside air system, contact your
distributor to have your appliance inspected
for the presence of the complete system. DO
NOT assume that you have this system in place.
Outside Air Control Lever
and Securing Screw Location
Outside Air Control Lever with Stop Behind
Securing Screw
Outside Air Shutter in the
Closed Position
Control Compartment Access Panel
Figure 36