![Astria Fireplaces Marin 40STTMN Assembly, Installation And Operation Instructions Download Page 40](http://html1.mh-extra.com/html/astria-fireplaces/marin-40sttmn/marin-40sttmn_assembly-installation-and-operation-instructions_2990900040.webp)
40
NOTE: DIAGRAMS & ILLUSTRATIONS ARE NOT TO SCALE.
Operation
900301-01 04/2017
Innovative Hearth Products
Marin™ See-Through B-Vent Gas Fireplaces
MAIN BURNER
FACTORY SHUTTER SETTING
Model
Natural Gas
inches (mm)
Propane Gas*
inches (mm)
Marin40ST
1/16 (1.5)
7/16 (11)
* If fi eld converted
WARNING
•
Air shutter adjustment should
only be performed by a quali-
fi ed professional service tech-
nician.
•
Ensure glass enclosure panels
are in place and sealed during
adjustment.
CAUTION
•
Soot will be produced if the
air shutter is closed too much.
Any damage due to sooting,
resulting from improperly
setting the air shutter, is not
covered under the warranty.
•
The air shutter door and
nearby appliance surfaces
are hot. Exercise caution to
avoid injury while adjusting
fl ame appearance.
1
. Refer to
Figure 43
for proper fl ame ap-
pearance. To adjust the fl ame, rotate the
adjustment rod toward the back or toward
the front of the fi replace (rod located in the
lower control area). Position the air shutter
to the factory setting as shown in the table
in
Figure 44
.
2.
Light appliance (follow lighting procedure
on lighting label in control compartment or
see lighting instructions on
Pages 45 and
46
)
.
3.
Allow the burner to operate for at least 15
minutes while observing the fl ame continu-
ously to ensure that the proper fl ame ap-
pearance has been achieved
.
If the following
conditions are present, adjust accordingly.
•
If
fl ame appears weak or sooty, adjust
the air shutter, incrementally, to a more
open position until the proper fl ame
appearance is achieved.
•
If
fl
ame
remains blue, adjust the air
shutter, incrementally, to a more closed
position until the proper fl ame appear-
ance is achieved.
4.
Leave the control knob (off/pilot/on) in the
ON position (millivolt appliances) and the
burner OFF/ON switch OFF (and remote
switches, if applicable).
5.
When satisfi ed that the burner fl ame appear-
ance is normal, re-install the lower control
compartment door.
MILLIVOLT
Thermocouple
Hood
Igniter Rod
3/8" Min
(9 mm)
Thermopile
Pilot
Nozzels
Millivolt Appliance Checkout
The pilot fl ame should be steady, not lifting
or fl oating. Flame should be blue in color with
traces of orange at the outer edge.
The top 3/8" (10 mm) at the pilot generator
(thermopile) and the top 1/8" minimum (tip)
of the quick drop out thermocouple should be
engulfed in the pilot fl ame.
The fl ame should project 1" (25 mm) beyond
the hood at all three ports
(see
Figure 45
)
.
Replace logs if removed for pilot inspection.
To light the burner; turn “ON” the control
switch and rotate the gas valve control knob
counterclockwise to the “ON” position (“ON”
will be at the top side of the valve).
Figure 45
Burner Flame Adjustments
Adjustment Rod Positions (when viewed from above)
Figure 44
Air Shutter
Adjusting
Rod
Orifice
Increase Shutter
Opening In This
Direction
Decrease Shutter
Opening In This
Direction
Note - Burners are omitted in this view for clarity.