background image

Inst 276 - Viron Connect Pool & Spa Controller V0610 
 

 

 

SETTING THE TEMPERATURE 

 

From the main menu, select the HEATING

 

icon

 

 

o

 

Your screen will show current and set temperatures

 

 

 

To change pool temperature setting, select POOL and use up and down arrows to set

 

temperature 

 

To change spa temperature setting, select SPA and use up and

 

down arrows to set

 

temperature.

 

 

LIGHTING OPERATION 

 

From the main menu, select the LIGHTING icon

 

 

o

  Your screen with show all available lighting zones. You can select ON / OFF or AUTO

 

modes 

for the lights. 

o

 

For  systems  using  AstralPool  Delta  LED  lighting,  you  can  change  colour  settings  from  this

 

menu also.

 

 

3 SPEED VIRON P300 (OPTIONAL - NOT INCLUDED) 

The Genus IV control system has the ability to control the speed of the Viron P300 3 speed high efficiency pump. 
 
The advantage of the Viron P 300 is its extremely low operating costs, reduced CO2 emissions and low operating 
noise.    The speed of the Viron pump is controlled via the touch pad on the motor of the pump. 
 
However, your Viron Connect Control system will allow speed control of your pump via the touchscreen console. 
 
When a Viron P300 pump is installed, the filter timeclock period should ideally be set for 12 hours per day.  For 
example, set the on period for 0800 hours and the operating hours for 12 hour operating period.  In this case, the 
pump will turn on at 8.00 am and turn off at 8.00 pm. 
 
Do not set the pump timer period to span midnight. 

 

Refer to Viron Pump instructions for explanation of the operation and speed settings of the Viron Pump. 

 

1.  The Viron P 300 has 3 speed settings 

– low, medium and high.   High Speed should be used when 

vacuuming the pool or operating spa jets or some water features such as water falls.   Medium speed can 
be used for gentle spa jet action, or filtration for the pool.   Low speed is the recommended setting for 
everyday filtration of your pool. 

 

2.  The Viron P300 will automatically start on high speed for the first 5 minutes to assist in priming and 

substantially fill the hair and lint pot with water.    After 5 minutes the pump will revert to the last speed it 
was set at before it was turned off. 

 

3.  During normal operation, it is recommended that the pump be operated on low speed for 12 hours per day.   

This will achieve the lowest operating costs with the lowest noise level.   Should your pool have areas 
where water is not turning over when pump is on low speed, increase the speed setting. 

 
 
 
 

Summary of Contents for Viron

Page 1: ...9350 2600 Sydney 02 9853 2100 Townsville 07 4750 3100 sales astralpool com au Brisbane 07 3308 5400 Adelaide 08 8152 7600 www astralpool com au Bolero ND Cleaner Viron Cartridge Filter INSTALLATION A...

Page 2: ...Inst 276 Viron Connect Pool Spa Controller V0610 2...

Page 3: ...iods 6 Setting favorites 6 Setting the temperature 7 Lighting operation 7 3 Speed Pump Control 7 Channel 1 Over ride switch 8 LCD Display 8 Fault Indication 8 Remote second touch pad console 8 INSTALL...

Page 4: ...e 1 x Touchscreen controller 1 x 15m Cable for Touchscreen Connection 1 x Installation and Operation Manual 1 x Set of mounting Screws and bracket OPTIONAL ACCESSORIES 1 Connect 8 Expansion Module Equ...

Page 5: ...on Setup Key in password 1234 and select done a Select CHANGE icon b LIGHTING ZONES i Select the number of lighting zones up to 4 This can include lights in the pool or garden lighting if connected An...

Page 6: ...elect one of the lighting zones set up earlier in the installation v Select NEXT g CHANNEL 2 thru 8 i Repeat steps as per CHANNEL 1 h IS CLEANING INTERLOCK REQUIRED i If you have infloor cleaning inst...

Page 7: ...demand is to operate in Pool or Spa mode Select DONE o Select the MENU icon to return to the main menu SETTING YOUR FAVORITES From the main menu select the equipment you want to have running as one o...

Page 8: ...a Viron P300 pump is installed the filter timeclock period should ideally be set for 12 hours per day For example set the on period for 0800 hours and the operating hours for 12 hour operating period...

Page 9: ...e purposes of backwashing maintenance etc This switch should be in the Auto position for normal remote and timer control The On position turns the pump on regardless of the timer and remote control se...

Page 10: ...ion Switch must be installed in the electrical supply to the Power Supply Module The Pool and Spa Equipment Centre is not intended for use by young children or infirm persons without supervision Pleas...

Page 11: ...n the Auto Position It should be left in the On position for normal operation and off for maintenance CONNECTION TO ASTRALPOOL ROLACHEM SYSTEMS The RolaChem dosing system needs to be connected to the...

Page 12: ...F button WARM COOL WARM WARM Release the ON OFF button Using the button located under the word next scroll through the menu until you arrive at the option Use Fast Comms Select change and make setting...

Page 13: ...on The LED next to the medium button should be flashing and the LED next to the high speed button should be constant on If not repeat process above VX S Series Salt Chlorinators To configure the VX se...

Page 14: ...lding in the ON OFF button and pressing in sequence WARM COOL WARM Configure control based on prompted options When option for slow or fast comms is displayed select Fast Comms YES You will also be pr...

Page 15: ...alve Configuration Cam Adjustment RETURN SIDE RETURN SIDE SUCTION SIDE SUCTION SIDE SPA RETURN POOL RETURN RETURN SPA RETURN RETURN POOL RETURN POOL SUCTION SPA SUCTION PUMP SUCTION POOL SUCTION SPA S...

Page 16: ...not limited to water ingress into Power Supply Module and Remote Control excessive appliance current load on any one or number of power outlets misuse or abuse whether intentional or accidental Astra...

Page 17: ...________________________________________________________ Channel 5 _________________________________________________________________ Channel 6 _________________________________________________________...

Page 18: ...Inst 276 Viron Connect Pool Spa Controller V0610 18...

Page 19: ...Inst 276 Viron Connect Pool Spa Controller V0610 19...

Page 20: ...South Australia Western Australia Gold Coast Townsville Ph 03 8796 8600 Ph 02 9853 2100 Ph 07 3308 5400 Ph 08 8152 7600 Ph 08 9350 2600 Ph 07 5552 2600 Ph 07 4750 3100 Fax 03 8796 8670 Fax 02 9853217...