background image

Inst 276 - Viron Connect Pool & Spa Controller V0610 
 

 
 

SETTING THE TIMERS 

 

From the main menu, select the TIMERS icon

 

 

o

 

Your screen will show 4 timer periods, all of which will be disabled by default.

 

 

 

To configure Timer 1, touch the SETUP

 

icon.

  

 

You can select which equipment you want to have activate during

 

Timer 1

 

 

Select

 

NEXT

 

 

You will be asked if you want the system operating in Pool or Spa mode (if enabled in

 

installation process) 

 

Select

 

NEXT

 

 

Choose if your heater is to be ON or OFF during

 

timer period

 

 

Select

 

NEXT

 

 

Select if lighting zones are to be active during timer

 

period

 

 

Select

 

NEXT

 

 

The default timer configuration screen will be displayed. 

 

Select the DISABLED icon next to the timer

 

period.

 

 

Set start and stop

 

times 

 

Select DONE 

 

Your timer period will now be displayed on the configuration

 

screen

 

o

 

Repeat process for remaining timer periods

 

if required

 

o

 

Set Heat Demand (if active)

 

 

Set start and

 

stop times

 

 

Set if demand is to operate in Pool or Spa mode

 

 

Select DONE

 

 

o

 

Select the MENU icon

 

to return to the main menu.

 

 

SETTING YOUR FAVORITES 

 

  

 

From the main menu, select the equipment you want to have running as one of your

 

favorite settings.

 

This may include having the spa light on, heater set to 36 degrees and the waterfall active.

 

 

 

Once you have activated all appliances you want on for the favorite

 

setting;

 

 

o

 

Select the SETUP icon from the main menu

 

 

Select CONFIGURE FAVOURITES 

 

Select the favourite you wish to set. You can alter the existing Pool or Spa

 

settings, or

 

you can create a new setting. Up to 6 new settings can be created.

 

 

If  you  want  to  create  a  new  favourite,  select  FAVOURITE

 

1.  You  can  then  edit  the

 

name of the favourite (e.g. “Night Party”) 

 

Select

 

DONE

 

 

To  save  settings  for  the  favourite,  select  the  SAVE  CURRENT

 

CONFIGURATION 

icon. A confirmation message will be displayed on the screen.

 

 

You  can  view  the  settings  of  any  favourite  program  by  selecting  the  VIEW

 

CONFIGURATION icon.

 

 

o

 

To activate a favourite setting, simply select the FAVOURITES icon from the main menu, they

 

pick the favourite setting from the options given.

 

 

 

 

Summary of Contents for Viron

Page 1: ...9350 2600 Sydney 02 9853 2100 Townsville 07 4750 3100 sales astralpool com au Brisbane 07 3308 5400 Adelaide 08 8152 7600 www astralpool com au Bolero ND Cleaner Viron Cartridge Filter INSTALLATION A...

Page 2: ...Inst 276 Viron Connect Pool Spa Controller V0610 2...

Page 3: ...iods 6 Setting favorites 6 Setting the temperature 7 Lighting operation 7 3 Speed Pump Control 7 Channel 1 Over ride switch 8 LCD Display 8 Fault Indication 8 Remote second touch pad console 8 INSTALL...

Page 4: ...e 1 x Touchscreen controller 1 x 15m Cable for Touchscreen Connection 1 x Installation and Operation Manual 1 x Set of mounting Screws and bracket OPTIONAL ACCESSORIES 1 Connect 8 Expansion Module Equ...

Page 5: ...on Setup Key in password 1234 and select done a Select CHANGE icon b LIGHTING ZONES i Select the number of lighting zones up to 4 This can include lights in the pool or garden lighting if connected An...

Page 6: ...elect one of the lighting zones set up earlier in the installation v Select NEXT g CHANNEL 2 thru 8 i Repeat steps as per CHANNEL 1 h IS CLEANING INTERLOCK REQUIRED i If you have infloor cleaning inst...

Page 7: ...demand is to operate in Pool or Spa mode Select DONE o Select the MENU icon to return to the main menu SETTING YOUR FAVORITES From the main menu select the equipment you want to have running as one o...

Page 8: ...a Viron P300 pump is installed the filter timeclock period should ideally be set for 12 hours per day For example set the on period for 0800 hours and the operating hours for 12 hour operating period...

Page 9: ...e purposes of backwashing maintenance etc This switch should be in the Auto position for normal remote and timer control The On position turns the pump on regardless of the timer and remote control se...

Page 10: ...ion Switch must be installed in the electrical supply to the Power Supply Module The Pool and Spa Equipment Centre is not intended for use by young children or infirm persons without supervision Pleas...

Page 11: ...n the Auto Position It should be left in the On position for normal operation and off for maintenance CONNECTION TO ASTRALPOOL ROLACHEM SYSTEMS The RolaChem dosing system needs to be connected to the...

Page 12: ...F button WARM COOL WARM WARM Release the ON OFF button Using the button located under the word next scroll through the menu until you arrive at the option Use Fast Comms Select change and make setting...

Page 13: ...on The LED next to the medium button should be flashing and the LED next to the high speed button should be constant on If not repeat process above VX S Series Salt Chlorinators To configure the VX se...

Page 14: ...lding in the ON OFF button and pressing in sequence WARM COOL WARM Configure control based on prompted options When option for slow or fast comms is displayed select Fast Comms YES You will also be pr...

Page 15: ...alve Configuration Cam Adjustment RETURN SIDE RETURN SIDE SUCTION SIDE SUCTION SIDE SPA RETURN POOL RETURN RETURN SPA RETURN RETURN POOL RETURN POOL SUCTION SPA SUCTION PUMP SUCTION POOL SUCTION SPA S...

Page 16: ...not limited to water ingress into Power Supply Module and Remote Control excessive appliance current load on any one or number of power outlets misuse or abuse whether intentional or accidental Astra...

Page 17: ...________________________________________________________ Channel 5 _________________________________________________________________ Channel 6 _________________________________________________________...

Page 18: ...Inst 276 Viron Connect Pool Spa Controller V0610 18...

Page 19: ...Inst 276 Viron Connect Pool Spa Controller V0610 19...

Page 20: ...South Australia Western Australia Gold Coast Townsville Ph 03 8796 8600 Ph 02 9853 2100 Ph 07 3308 5400 Ph 08 8152 7600 Ph 08 9350 2600 Ph 07 5552 2600 Ph 07 4750 3100 Fax 03 8796 8670 Fax 02 9853217...

Reviews: