Inst 276 - Viron Connect Pool & Spa Controller V0610
11
CONNECTION TO VIRON P300 3 SPEED PUMPS
1. Turn power off to Pump.
2. Loosen gland at rear of capacitor cover on P300 pump.
3. Connect RJ12 cable in connection socket (Cable not supplied)
4. Your Remote Control is now ready for operation.
CONNECTION TO ASTRALPOOL SALT CHLORINATORS
The VX s Model Chlorinator control needs to be connected to the equipment centre via a remote cable. To
connect the cable from the Chlorinator Control to the equipment centre, do the following:
1. Turn off the mains supply to the equipment centre.
2. Plug one end of the RJ12 cable into the RJ12 socket that can be found on the underside of the Power
Supply Module. (Cable not supplied)
3. The other end o
f the cable must be plugged into the VX „S‟ model chlorinator.
4. Connect the chlorinator mains plug into the pump outlet of the Power Supply Module.
5. Plug the pump into the power socket located on the underside of the VX chlorinator.
6. Set the Pump override switch to the
Off
position.
7. Turn on the mains to the Equipment centre.
8. Whilst holding down the Backwash and Power level down buttons, turn the Pump override switch to
ON.
The
Chlorinator should indicate a standalone setting. Refer to page 13 section labelled VX chlorinators.
NOTE: The pump Override switch should no longer be used in the “Auto” Position. It should be left in the
On position for normal operation and off for maintenance.
CONNECTION TO ASTRALPOOL ROLACHEM SYSTEMS
The RolaChem dosing system needs to be connected to the equipment centre via a remote cable. To connect the
cable from the dosing system to the equipment centre, do the following:
1. Turn off the mains supply to the equipment centre.
2. Plug one end of the RJ12 cable into the RJ12 socket that can be found on the underside of the Power
Supply Module. (Cable not supplied)
3. The other end of the cable must be plugged into the Rolachem dosing system.
4. Connect the chlorinator mains plug into the pump outlet of the Power Supply Module.
5. Plug the pump into the power socket located on the underside of the Rolachem dosing system.
6. Set the Pump override switch to the
ON
position.
7. Turn on the mains to the Equipment centre.
8. Refer to the programming guide for the RolaChem dosing system for configuration to suit operation with
Genus control systems.
NOTE: The pump Override switch should no longer be used in the “Auto” Position. It should be left in the
On position for normal operation and off for maintenance.
INTERFACE FOR NON ASTRALPOOL SALT CHLORINATORS (OPTION)
1. Connect the male 4 pin plug into one of the female 4 pin sockets of the Power Supply Module.
2. Cut the sense wire on Salt Chlorinator and crimp in blue wires from Salt Chlorinator Interface.
Note:
If Chlorinator output is disabled when in Pool mode, swap white and red leads
inside Salt Chlorinator Interface.