Inst 276 - Viron Connect Pool & Spa Controller V0610
12
PRODUCT COMPATIBILITY
Heater Requirements
Only the Viron series Pool and Spa heaters are fully compatible with the Viron Connect control system. To control
a Viron Pool and Spa heater using the Viron Connect system, you must configure the communication system to
Fast Comms on the Viron heater (heaters manufactured from March 2010 are compatible). This is done by;
With the heater powered but indicating OFF on the screen
Press and hold in the ON/OFF button
Press in sequence (while holding in ON/OFF button) WARM / COOL / WARM / WARM
Release the ON/OFF button
Using the button located under the word next, scroll through the menu until you arrive at the option “Use
Fast Comms”
Select change and make settings fast comms
Next in the menu an option “POOL/SPA MASTER” is displayed. Select change
Change setting to P/S Master Off
If no heater is to be installed on the system (or a different model, manufacturers heater is to be used), the Viron
Connect must be configured to operate in LOCAL mode. You must also purchase a Viron Connect Temp Sensor
Pack. To change the controller to local mode;
Remove from cover from the controller electrical box (ensure power is isolated)
Reposition jumper on CN4 from SYSTEM (top and middle pins) to LOCAL (middle and bottom) setting