7.7.4. PH/ORP SET POINT PROGRAMMING
Keep the
“SET” [24]
key pressed until the light displays the desired pH value within the 7.0
– 7.8 range. Then release the key.
In order to program the ORP set point on the system, keep the
“SET” [26]
key pressed until the
light displays the ORP desired within the 650 – 850 mV range. Then, release the key.
7.7.5. ALARMS
HIGH SALT LEVEL
If too much salt has been added, the production level will automatically fall beneath the se-
lected level. The
“HIGH SALT” [7]
light will stay on. In this case, empty part of the pool (0%,
for instance) and add fresh water to reduce the salt concentration.
LOW SALT LEVEL
If there is less than the recommended salt content in the pool, the selected output level can-
not be reached. The
“LOW SALT” [6]
light will stay on. In this case, measure the salt level in
the water and add the required amount of salt. The common salt (NaCl) used for electrolysis
should not contain additives (anti-caking agents, iodine) and must be suitable for human con-
sumption. The system may indicate a low salt level if the temperature falls beneath 0ºC.
To precisely measure the salt level, we recommend the use of a portable salinity-temperature
meter.
•
•