S I G N A T U R E
6
In normal conditions, the production value
[4]
should be the same as the programmed value,
however, if the salt level in the water is outside the permitted range (
“HIGH SALT” [7]
or
“LOW
SALT” [6]
alarms on), or there is a problem in the electrolysis cell (
“ELECTRODES” [13]
alarm
on), the production value
[4]
could be lower than the programmed and displayed value
[11]
.
7.7.3. SALINITY TEST
AstralPool Chlore Elite systems have an integrated system to detect the salinity level of pool
water. To run the test press the
“SALT TEST” [9]
key. During the test, the production light will
range from 0%-80% of the salinity scale
[5]
, alternately displaying
“SALT”
and
“TEST”
on the
system information screen
[11]
. Once the test is completed, the light will blink for a few seconds
on the scale
[5]
on the detected salinity value. The equipment will return to normal operating
mode after a few seconds.
The system might show lower than actual salt levels if the temperature falls beneath 0ºC.
NORMAL
EXCESS
HIGH
LOW
VERY LOW