Astraada DRV-28A inverters
-149-
Function
code
Name
Description
Default Modify
when the present motor is motor 1, only
P02.06, P02.07 and P02.08 are autotuned;
when the present motor is motor 2, only
P12.06, P12.07 and P12.08 are autotuned.
4: Rotary autotuning 2. Similar to rotary
autotuning 1, but it is valid only for AMs.
5: Static autotuning 3 (partial autotuning), valid
only for AMs.
P00.16
AVR function
selection
0: Invalid
1: Valid during the whole procedure
The auto-adjusting function of the VFD can
eliminate the impact on the output voltage of
the VFD because of the bus voltage
fluctuation.
1
○
P00.17
VFD type
0: G type
1: P type
0
◎
P00.18
Function parameter
restore
0: No operation
1: Restore default values
2: Clear fault records
Note:
After the selected operation is
performed, the function code is automatically
restored to 0. Restoring the default values
may delete the user password. Exercise
caution when using this function.
0
◎
P01 group––Start and stop control
P01.00
Start mode
0: Direct start
1: Start after DC braking
2: Speed tracking restart 1
3: Speed tracking restart 2
0
◎
P01.01
Starting frequency
of direct start
The function code indicates the initial
frequency during VFD start. See P01.02
(Starting frequency hold time) for detailed
information.
Setting range: 0.00–50.00Hz
0.50Hz
◎