Astraada DRV-28A inverters
-243-
Function
code
Name
Description
Default Modify
division angle 2
P22.09
Spindle scale-
division angle 3
Setting range: 0.00–359.99
45.00
○
P22.10
Spindle scale-
division angle 4
Setting range: 0.00–359.99
60.00
○
P22.11
Spindle scale-
division angle 5
Setting range: 0.00–359.99
90.00
○
P22.12
Spindle scale-
division angle 6
Setting range: 0.00–359.99
120.00
○
P22.13
Spindle scale-
division angle 7
Setting range: 0.00–359.99
180.00
○
P22.14 Spindle drive ratio
This function code sets the reduction ratio of
the spindle and the mounting shaft of the
encoder.
Setting range: 0.000–30.000
1.000
○
P22.15
Zero-point
communication
setup of spindle
sets spindle zero-point offset, if the
selected spindle zero point is P22.03, the final
spindle zero point will be the sum of P22.03
Setting range: 0–39999
0
○
P22.16
Reserved
0–65535
0
○
P22.17
Reserved
0–65535
0
○
P22.18
Rigid tapping
selection
Ones place: Whether to enable
0: Disable (but can be enabled through
terminal, using function 58)
1: Enable (internally enabled)
Tens place: Analog port selection
0: Invalid
1: AI1
2: AI2
3: AI3
0x00
◎
P22.19
Analog filter time of
rigid tapping
0.0ms–1000.0ms
1.0ms
○
P22.20
Max. frequency of
rigid tapping
0.00–400.00Hz
50.00Hz
○
P22.21
Corresponding
0.00–10.00Hz
0.00Hz
○
Summary of Contents for AS28DRV4011A