![Astoria Gloria AEP Instruction Manual For User Download Page 195](http://html.mh-extra.com/html/astoria/gloria-aep/gloria-aep_instruction-manual-for-user_2990333195.webp)
47
English
DISPLAY - ASD / DS
ENGLISH
1) Place the programming key in the
OFF
position
;
2) hold down the key PROG of the left push button panel for 5 seconds;
3) place the programming key in the
ON
position
;
4) to start resetting press the key ;
5) to confirm resetting press the key for 3 seconds.
data reset
reset counting ?
press + 3 sec.
espresso gr1
00000000
The procedure described above makes it possible to reset the counts of the single selections (group
1-2-3, milk selections), but not to reset the machine completely (machine life cycle).
Only the selections that use coffee, of the milk selections push button panel, will increase the total
count of the machine.
i
15.2 Resetting selection count to zero
1) Turn the programming switch to
ON;
2) Simultaneously press the 4 keys PROG
of the left push button panel until the display shows the signal.
3) to bypass regeneration control, set a value of
00000
litres.
15.3 Reset of water litres count for softener regeneration
1.0 bar 120°C
BOILER filling
cause
solution
1.1 bar 120°C
filling timeout
Boiler filled with water when using the
machine for the first time or when refilling
to reach the water level.
doser alarm
Wait for the boiler to be completely filled.
reg. softener
Time for filling the boiler with water longer
than expected.
Make sure the water mains cock is opened.
Switch the machine off and back on again. If
the warning is still on after a few attempts, call
Technical Assistance.
1) Grinding too fine.
2) Water supply valve closed
3) Fault of the volumetric electronic control
1) Adjust the grinding.
2) Open the water supply valve
3) Stop dispensing by pressing the serving key and
call technical service
Lack of water softener regeneration.
Carry out the water softener regeneration.
To eliminate this signal see chapter 15.3
If the machine will not work call technical assistance.
i
Normal activation of time limit upon first
filling of boiler with water.
Switch the machine off and back on again.
16.
S
ignals
reg. softener
00000
reg. softener
00000
Summary of Contents for Gloria AEP
Page 2: ......
Page 3: ......
Page 4: ......
Page 6: ......
Page 24: ......
Page 34: ......
Page 52: ......
Page 54: ......
Page 72: ......
Page 82: ......
Page 100: ......
Page 102: ......
Page 120: ......
Page 130: ...30 français ...
Page 148: ......
Page 150: ......
Page 168: ......
Page 178: ...30 English ...
Page 196: ......
Page 198: ......
Page 216: ......
Page 226: ...30 deutsch ...
Page 244: ......
Page 246: ......
Page 264: ......
Page 274: ......
Page 292: ......
Page 293: ......
Page 294: ......
Page 295: ......