Symptoms
Possible Causes
Solutions
than the internal ambient
temperature, the time
setting must not be zero
“0”
7. Check the fuses on
the main control board
replace if necessary.
8. Verify all water supply
valves are open
The steam light flashes
for 40 seconds and then
turns off
1. No water in the steam
unit, safety protection
1. Check that the
plumbing to the steam
unit is correct
2. Check that you are
getting voltage to the
inlet valve. When
operation you should
hear a click from the
valve if not replace
3. Check and clean the
inlet filter
Water comes out of the
steam outlet instead of
steam
1. Issue with the water
level sensor
2. Scale build up in the
water level sensor
1. Check all wiring to the
water level sensor is
secure replace if
necessary
2. Remove and clean the
scale from the sensor
No water from one or
more body jets
1. Diverter in wrong
position
2. Blown fuse
3. Valve bank issue
1. Verify that the diverter
valve is in the correct
position for body jets
2. Check the fuse for the
valve bank located on
the power line feeding
the valve bank just above
the bank.
3. Verify power to valve
bank you should hear a
click from each of the
operating valves replace
if necessary
47