3
of 4
Changing the Alternate Lens
on the Securitron EEB2
1.
GRASP and TURN OVER the keyplate.
2.
From the back, ROTATE the white contact block of
the switch counterclockwise to the 11:00 o’clock
position, and PULL straight back to remove.
3.
SLIDE a slender smooth-ended object, such as a marker
pen, inside the switch body up against the lens.
4.
PLACE the object on a smooth surface with the
keyplate on top, and TAP the keyplate up and
down on the object to pop off the lens.
5.
REMOVE the lens and insert.
6.
TURN OVER the keyplate and PLACE a new
insert onto the front of switch.
7.
ENSURE that the text on the insert is correctly reading to the
keyplate, and PLACE the matching color lens on top of insert.
8.
PRESS around all edges of the lens until it snaps in place.
9.
DEPRESS lens several times to ensure smooth
operation and the lens is not binding.
10.
With the terminals upward, INSERT the contact block back
into the back of the switch at the 11:00 o’clock position and
ROTATE clockwise until it stops straight up and down.
To Lock
“+” Wire
To + V
+ 12 V or + 24 V
0 V
(DC Neg)
Diagram 3:
Internal Schematic
NOTE:
Positive input voltage on the white wire must be from the
same power source that the red and black wires are connected.
NC
C
C
NC
NO
Trigger
+
–
Green
Alternate
Lens
White
Red
Black
Timer
Push
Button