04/30/21
1-800-810-WIRE • www.sargentlock.com • A8151H 11
Copyright © 2016, 2019, 2021, Sargent Manufacturing Company
, an ASSA ABLOY Group company
. All rights reser
ved.
Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.
IN120 / IN220 Mortise Lock
Order of installation may vary. Refer to appropriate sections for instructions.
Hinge-side harness connectors:
• 4-pin male Molex connector
• 6-pin male Molex connector with ground wire
Lock-side harness connectors:
• Ring terminal
• Male RJ45 connector
(crimped after cable is fed through door)
Notes:
• Connectors go on only one way. They cannot be plugged to incorrect position.
• Do not force and do not offset connectors.
• Be sure they are completely seated (flush).
Order of installation may vary. Refer to appropriate sections for instructions.
1. Prop door open.
2. Using the ring terminal, carefully route the assembly through the door
channel toward lock.
PoE Door Harness
IN220 PoE Lock
4-pin F
4-pin M
4-pin F
6-pin F
6-pin F
6-pin M
Cable
: CAT 5e (or higher),
26 AWG stranded,
shielded, 100ohm
Drain Wire
PoE Lock
D
C
RJ45-M
IN220 (PoE) Installation Wiring (Continued)
*Do not terminate PoE harness (with RJ45 M) until
cable has been routed through door and inside
mounting plate assembly.
See Section 9,
S
tep
10 - Installation of Connectors.
PoE Harness
(Cat 5e or higher) with
ground wire