SE LP10 7000 Series Multi Point Lock

The SARGENT SE LP10 brings flexibility to our Integrated Wired access control solutions for the 

7000 series multipoint locks. Featuring multiCLASS SE® Technology from HID Global®, the SE LP10 

is ideal for mixed credential environments and enables easy migration to higher  security credentials 

and mobile access. Backed by SARGENT’s Grade 1 hardware, SE LP10 multipoint locks include 

an external Door Position Switch (DPS) for door position monitoring, and other monitoring options, 

such as latchbolt and lever monitoring, are available as add-ons. The SE LP10 reader provides visual 

(LED) and audible indicators of lock state (locked/unlocked).

•  Fire rated devices available
•  Multi point lock furnished for 1-3/4” doors
•  Fail safe or fail secure* available
•  Door Position Switch (DPS 3287) supplied 

for monitoring

•  24VDC motor-operated ET Trim available
•  Wire from EAC Panel to door must be shielded 

with a drain terminated at EAC Panel controller

SE LP10 7000 Series Multi Point Lock

• Cylinder override available for 7000 CVR with  

   106 Series Auxiliary Control

General Description

3

Specifications / Features

4

All SE LP10 Multi Point Locks

Compliance with IEEE 802.3 (at or af) specifications was not verified as part of UL294/B.

•    

 Outside lever can be controlled by multiple credential formats: 

     • 

125 kHz credential compatibilty

:

         

• 

HID Prox®, AWID, EM4102

• 

13.56 MHz credential compatibility:

• 2.4 GHz credential compatibility 

• Secure Identity Object

 (SIO) on Mobile IDs (Bluetooth Smart)

• Secure Identity Object™ (SIO) on iCLASS Seos, iCLASS SE/SR,  

   MIFARE DESFire EV1/EV2 and MIFARE Classic (on by default)
• Standard iCLASS Access Control Application, ISO14443A (MIFARE) 

   CSN, ISO14443B CSN, and ISO15693 CSN
• ISO14443A/B (PIV-compatible Transparent FASC-N read) available 

   with SE LP10-F (**not available with Alternate Indicator Configuration) 
• NFC-enabled mobile phones

For Mobile Credential-Enabled versions of this electronic lock

 

(Indicated by “BIPS” in the product order string):
  • Mobile Credentials are transmitted to the lock via Bluetooth Smart or NFC ISO/IEC14443 and 

     must use a mobile device enabled with these technologies.
  • Credential and mobile device versions are specified by the credential provider.
  • User must acquire the latest HID “Mobile Access” application available from Apple iStore or 

     Android PlayStore.

*WARNING: The system shall not be installed in the fail-secure mode unless permitted by the lo-

cal authority having jurisdiction and shall not interfere with the operation of Listed panic hardware.

**not available with Alternate Indicator Configuration

Summary of Contents for Sargent ELR Series

Page 1: ...mpany an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited Series ELR Multi Point Lock...

Page 2: ...cturing Company is prohibited 05 31 20 A8239B 800 810 WIRE 9473 www sargentlock com 2 SE LP10 7000 Series Multi Point Lock Regulatory Compliance 3 Warning 3 General Description 4 Specifications Featur...

Page 3: ...n reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the rece...

Page 4: ...CVR with 106 Series Auxiliary Control General Description 3 Specifications Features 4 All SE LP10 Multi Point Locks Compliance with IEEE 802 3 at or af specifications was not verified as part of UL294...

Page 5: ...14 14 12 12 10 250 18 16 14 14 12 12 12 10 300 18 16 14 12 12 12 10 400 18 14 12 12 10 10 500 16 14 12 10 10 750 14 12 10 10 1 000 14 10 10 1 500 12 10 Wire Gauge Chart 24VDC Electrical Specifications...

Page 6: ...PIV credential causes LED to turn amber as credential is authenticated Reader emits a short beep when credential is successfully read Reference Diagram 1 PIN 4 Tan DPS COM PIN 2 Gray Lock POS PIN 1 V...

Page 7: ...Blue 6 EARTH GROUND Brown 7 TAMPER Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 12VDC DATA 1 DATA 0 RX NO RX COM Electrical Access Control Panel By Others Use NC for Fail...

Page 8: ...Orange 5 RX COM Blue 6 EARTH GROUND Brown 7 GREEN_LED Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 12VDC DATA 1 DATA 0 RX NO RX COM Electrical Access Control Panel By Oth...

Page 9: ...or in part without express written permission of Sargent Manufacturing Company is prohibited SE LP10 7000 Series Multi Point Lock Tools Required Phillips screw driver standard size Slotted screw drive...

Page 10: ...ufacturing Company is prohibited 05 31 20 A8239B 800 810 WIRE 9473 www sargentlock com 10 SE LP10 7000 Series Multi Point Lock 2 6 5A 19 10 1 3A 4 7 23 22 Parts Breakdown Continued 6 Tools Required Ph...

Page 11: ...Not shown 1 10 97 4056 I S ELR Escutcheon Assembly 1 11 650 Top Strike Pack not shown 606 Bottom Strike Pack Fire 12 HC WS not shown 652 Top and Bottom Strike Pack STD not shown 12 52 4922 BIPS 03 Re...

Page 12: ...tal doors 2 Refer to instruction sheet A7971 for rod and inner case installation on wood doors Check hand of door The Multi Point lock may be handed Door should be fitted and hung Verify box label for...

Page 13: ...rface Fig 3A 2 Feed wire through the through hole and attach the outside exit trim to the door A Outside Trim 3 Install Outside Trim and Inside Trim B Inside Trim Fig 3A Outside Exit trim Fig 3B Insid...

Page 14: ...or Fig 5B 2 Align top of reader with top of backplate Pivot reader down until seated Guide wires as needed to avoid pinching 3 Secure the reader with 1 6 32 x 3 8 Phillips or anti tamper security torx...

Page 15: ...and Wire Connections Non ELR 1 Attach mounting plate using 2 8 x 1 2 self drilingl screws Fig 6A 2 Connect 6 and 2 pin connectors from device to 6 and 2 pin connectors on reader harness Fig 6B C 3 Co...

Page 16: ...ening in ELR assembly 3 Slide the mounting clip of the ELR assembly underneath the installed screw and tighten it to secure the assembly in place Note Be careful not to pinch or disconnect the wire lo...

Page 17: ...1 4 Phillips pan head self drilling screws Note For non fire rated doors omit fire plate 8A Position Inside Escutcheon Wires Non ELR 1 Carefully and neatly fold lock body wires onto themselves Electro...

Page 18: ...ified use SARGENT template A7448B to prepare door and frame at desired location 3 Connect the common wire of the switch to the common input terminal of the EAC 4 Connect the normally open wire of the...

Page 19: ...t the product s features and capabilities Wiegand Test Unit If the lock fails to operate when DC voltage is applied A Remove power B Confirm the polarity of the supply i e is positive If the lock is f...

Page 20: ...applications The company s customer base includes commercial construction institutional and industrial markets Copyright 2020 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reser...

Reviews: