SE LP10 7000 Series Multi Point Lock
Inside of Door
6A Inside Mounting Plate and Wire Connections (Non-ELR)
1. Attach mounting plate using (2) #8 x 1/2” self-drilingl screws (Fig. 6A).
2. Connect 6- and 2-pin connectors from device to 6- and 2-pin connectors on reader
harness (Fig. 6B, C).
3. Connect ElectroLynx 4- and 8-pin connectors from the door harness to (black) 4- and 8-pin
connectors of the SE LP10 harness (Fig. 6D).
NOTE: Neatly fold excess wires into remaining space to prevent pinching
wires when mounting inside escutcheon (Fig. 6E).