Assa Abloy Sargent ELR Series Installation Instructions Manual Download Page 3

05/31/20

A8239B • 800-810-WIRE (9473) • www.sargentlock.com

3

Copyright © 2020, Sargent Manufacturing Company

, an ASSA ABLOY Group company

. All rights reser

ved. 

Reproductions in whole or in part without express written permission of Sargent Manufacturing Company is prohibited.

SE LP10 7000 Series Multi Point Lock

Changes or modifications to this unit not expressly approved by the party responsible 
for compliance could void the user’s authority to operate the equipment.

To avoid possible damage from electrostatic discharge (ESD), some basic precautions should be used when handling electronic components:
• 

 Minimize build-up of static by touching and/or maintaining contact with unpainted metal surfaces such as door hinges, latches, and  

          mounting plates especially when mounting electronic components such as readers and controllers onto the door.
• 

Leave components (reader and controller) protected in their respective anti-static bags until ready for installation

• 

Do not touch pins, leads or solder connections on the circuit boards

This product can expose you to lead which is known to the state of California to cause cancer and birth defects or other reproductive harm.  

For more information go to: 

www.P65warnings.ca.gov

.

Ce produit peut vous exposer au plomb qui, dans l’état de la Californie, est reconnu pour causer le cancer, des anomalies congénitales ou 

d’autres problèmes de reproduction.
Pour plus d’informations, visitez: 

www.P65warnings.ca.gov

.

Any retrofit or other field modification to a fire rated opening can potentially impact the fire rating of the opening, and SARGENT Manufacturing 

makes no representations or warranties concerning what such impact may be in any specific situation. When retrofitting any portion of an existing 

fire rated opening, or specifying and installing a new fire-rated opening, please consult with a code specialist or local code official (Authority 

Having Jurisdiction) to ensure compliance with all applicable codes and ratings.

!

FCC

:

This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These 

limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses, and 

can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio 

communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful 

interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the 

interference by one or more of the following measures:

• 

Reorient or relocate the receiving antenna.

• 

Increase the separation between the equipment and receiver.

• 

Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.

• 

Consult the dealer or an experienced radio/TV technician for help.

Industry Canada:

This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations. Operation is subject to the 

following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including 

interference that may cause undesired operation. 

Cet appareillage numérique de la classe B répond à toutes les exigences de l’interférence canadienne causant des règlements d’équipement. 

L’opération est sujette aux deux conditions suivantes: (1) ce dispositif peut ne pas causer l’interférence nocive, et (2) ce dispositif doit accepter 

n’importe quelle interférence reçue, y compris l’interférence qui peut causer l’opération peu désirée.

This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and 

operated with minimum distance 20cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with 

any other antenna or transmitter.

Cet équipement est conforme aux limites d’exposition aux radiations de la FCC définies pour un environnement non contrôlé. Cet équipement doit 

être installé et utilisé à une distance minimale de 20 cm entre le radiateur et votre corps. Cet émetteur ne doit pas être co-localisé ou fonctionner en 

conjonction avec une autre antenne ou un autre émetteur.

Under Industry Canada regulations, this radio transmitter may only operate using an antenna of a type and maximum (or lesser) gain approved for 

the transmitter by Industry Canada. To reduce potential radio interference to other users, the antenna type and its gain should be so chosen that the 

equivalent isotropically radiated power (e.i.r.p.) is not more than that necessary for successful communication.

Conformément à la réglementation d’Industrie Canada, le présent émetteur radio peut fonctionner avec une antenne d’un type et d’un gain maximal 

(ou inférieur) approuvé pour l’émetteur par Industrie Canada. Dans le but de réduire les risques de brouillage radioélectrique à l’intention des autres 

utilisateurs, il faut choisir le type d’antenne et son gain de sorte que la puissance isotrope rayonnée équivalente (p.i.r.e.) ne dépasse pas l’intensité 

nécessaire à l’établissement d’une communication satisfaisante.

1

Regulatory Compliance

 

2

Warning

Summary of Contents for Sargent ELR Series

Page 1: ...mpany an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited Series ELR Multi Point Lock...

Page 2: ...cturing Company is prohibited 05 31 20 A8239B 800 810 WIRE 9473 www sargentlock com 2 SE LP10 7000 Series Multi Point Lock Regulatory Compliance 3 Warning 3 General Description 4 Specifications Featur...

Page 3: ...n reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the rece...

Page 4: ...CVR with 106 Series Auxiliary Control General Description 3 Specifications Features 4 All SE LP10 Multi Point Locks Compliance with IEEE 802 3 at or af specifications was not verified as part of UL294...

Page 5: ...14 14 12 12 10 250 18 16 14 14 12 12 12 10 300 18 16 14 12 12 12 10 400 18 14 12 12 10 10 500 16 14 12 10 10 750 14 12 10 10 1 000 14 10 10 1 500 12 10 Wire Gauge Chart 24VDC Electrical Specifications...

Page 6: ...PIV credential causes LED to turn amber as credential is authenticated Reader emits a short beep when credential is successfully read Reference Diagram 1 PIN 4 Tan DPS COM PIN 2 Gray Lock POS PIN 1 V...

Page 7: ...Blue 6 EARTH GROUND Brown 7 TAMPER Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 12VDC DATA 1 DATA 0 RX NO RX COM Electrical Access Control Panel By Others Use NC for Fail...

Page 8: ...Orange 5 RX COM Blue 6 EARTH GROUND Brown 7 GREEN_LED Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 12VDC DATA 1 DATA 0 RX NO RX COM Electrical Access Control Panel By Oth...

Page 9: ...or in part without express written permission of Sargent Manufacturing Company is prohibited SE LP10 7000 Series Multi Point Lock Tools Required Phillips screw driver standard size Slotted screw drive...

Page 10: ...ufacturing Company is prohibited 05 31 20 A8239B 800 810 WIRE 9473 www sargentlock com 10 SE LP10 7000 Series Multi Point Lock 2 6 5A 19 10 1 3A 4 7 23 22 Parts Breakdown Continued 6 Tools Required Ph...

Page 11: ...Not shown 1 10 97 4056 I S ELR Escutcheon Assembly 1 11 650 Top Strike Pack not shown 606 Bottom Strike Pack Fire 12 HC WS not shown 652 Top and Bottom Strike Pack STD not shown 12 52 4922 BIPS 03 Re...

Page 12: ...tal doors 2 Refer to instruction sheet A7971 for rod and inner case installation on wood doors Check hand of door The Multi Point lock may be handed Door should be fitted and hung Verify box label for...

Page 13: ...rface Fig 3A 2 Feed wire through the through hole and attach the outside exit trim to the door A Outside Trim 3 Install Outside Trim and Inside Trim B Inside Trim Fig 3A Outside Exit trim Fig 3B Insid...

Page 14: ...or Fig 5B 2 Align top of reader with top of backplate Pivot reader down until seated Guide wires as needed to avoid pinching 3 Secure the reader with 1 6 32 x 3 8 Phillips or anti tamper security torx...

Page 15: ...and Wire Connections Non ELR 1 Attach mounting plate using 2 8 x 1 2 self drilingl screws Fig 6A 2 Connect 6 and 2 pin connectors from device to 6 and 2 pin connectors on reader harness Fig 6B C 3 Co...

Page 16: ...ening in ELR assembly 3 Slide the mounting clip of the ELR assembly underneath the installed screw and tighten it to secure the assembly in place Note Be careful not to pinch or disconnect the wire lo...

Page 17: ...1 4 Phillips pan head self drilling screws Note For non fire rated doors omit fire plate 8A Position Inside Escutcheon Wires Non ELR 1 Carefully and neatly fold lock body wires onto themselves Electro...

Page 18: ...ified use SARGENT template A7448B to prepare door and frame at desired location 3 Connect the common wire of the switch to the common input terminal of the EAC 4 Connect the normally open wire of the...

Page 19: ...t the product s features and capabilities Wiegand Test Unit If the lock fails to operate when DC voltage is applied A Remove power B Confirm the polarity of the supply i e is positive If the lock is f...

Page 20: ...applications The company s customer base includes commercial construction institutional and industrial markets Copyright 2020 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reser...

Reviews: