SE LP10 7000 Series Multi Point Lock

ITEM

PART # 

Description

Req.

1

WD/MD/AD Inside Trim Assembly

1

2

Outside Trim Assembly

1

3A

94-2411

MD/AD Inner Chassis Assembly

1

94-2412

MD/AD Inner Chassis Assembly, Fire (12-)

94-2414

MD/AD Monitoring Inner Chassis, Fire (53-/12-53-)

3B

94-2423

WD Inner Chassis Assembly (Not shown)

1

94-2424

WD Monitoring Inner Case (53-) (Not shown)

4

68-0888

Bottom Case

1

5A

MD694T

MD/AD Top Rod and Bolt Assembly

1

5B

WD694T

WD Top Rod and Bolt Assembly (Not shown)

1

6

68-5374

Top Case Assembly

1

7

694B

Bottom Rod and Bolt Assembly

1

8

97-0825

Standard Plate (Rectangular) (Not shown)

2

97-0826

Scultped Plate (Optional) (Not shown)

1

9

68-1264

WD Top Case Bracket (Not shown)

1

10

97-4056

I/S ELR Escutcheon Assembly

1

11

650

Top Strike Pack (not shown)

606

Bottom Strike Pack, Fire (12-)(HC)(WS) (not shown)

652

Top and Bottom Strike Pack, STD (not shown)

12

52-4922

BIPS-03 Reader and Harness Assembly - Bluetooth (Standard Indicator Configuration)

1

52-4528

FIPS-03 Reader & Harness Assembly - 200 bit Wiegand output

52-4567

FIPS-04 Reader & Harness Assembly - 75 bit Wiegand output 

52-4524

IPS-03 Reader & Harness Assembly (Standard Indicator Configuration)

52-5998

IPS-0E Reader & Harness Assembly (Alternate Indicator Configuration)

52-5999

BIPS-0E Reader & Harness Assembly - Bluetooth (Alternate Indicator Configuration)

13

-

SE Mounting Plate

14

52-1359

Trim Bezel 

1

15

52-4542

Fire Block Kit

1

16

52-1711

Gasket (for non-fire-rated doors)

1

17

52-5219

I/S Mounting Plate

1

18

97-0801

I/S SE LP10 Escutcheon

1

19

52-4722

ELR Assembly

1

20

94-2415

MD/AD Screw Pack

1

21

94-2431

WD Screw Pack (shown as Item 20)

1

22

52-4539

Screw Pack, SE Series

1

23

52-4723

MD/AD Mounting Hardware

1

24

52-4724

WD Mounting Hardware (shown as Item 23)

25

01-9241

#3 - 48 x 1/8” Pan head Machine Screw (Not shown)

Parts Breakdown (Continued)

6

SE LP10 7000 Series  

 

 

 

 

      

Summary of Contents for Sargent ELR Series

Page 1: ...mpany an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited Series ELR Multi Point Lock...

Page 2: ...cturing Company is prohibited 05 31 20 A8239B 800 810 WIRE 9473 www sargentlock com 2 SE LP10 7000 Series Multi Point Lock Regulatory Compliance 3 Warning 3 General Description 4 Specifications Featur...

Page 3: ...n reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reorient or relocate the rece...

Page 4: ...CVR with 106 Series Auxiliary Control General Description 3 Specifications Features 4 All SE LP10 Multi Point Locks Compliance with IEEE 802 3 at or af specifications was not verified as part of UL294...

Page 5: ...14 14 12 12 10 250 18 16 14 14 12 12 12 10 300 18 16 14 12 12 12 10 400 18 14 12 12 10 10 500 16 14 12 10 10 750 14 12 10 10 1 000 14 10 10 1 500 12 10 Wire Gauge Chart 24VDC Electrical Specifications...

Page 6: ...PIV credential causes LED to turn amber as credential is authenticated Reader emits a short beep when credential is successfully read Reference Diagram 1 PIN 4 Tan DPS COM PIN 2 Gray Lock POS PIN 1 V...

Page 7: ...Blue 6 EARTH GROUND Brown 7 TAMPER Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 12VDC DATA 1 DATA 0 RX NO RX COM Electrical Access Control Panel By Others Use NC for Fail...

Page 8: ...Orange 5 RX COM Blue 6 EARTH GROUND Brown 7 GREEN_LED Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 12VDC DATA 1 DATA 0 RX NO RX COM Electrical Access Control Panel By Oth...

Page 9: ...or in part without express written permission of Sargent Manufacturing Company is prohibited SE LP10 7000 Series Multi Point Lock Tools Required Phillips screw driver standard size Slotted screw drive...

Page 10: ...ufacturing Company is prohibited 05 31 20 A8239B 800 810 WIRE 9473 www sargentlock com 10 SE LP10 7000 Series Multi Point Lock 2 6 5A 19 10 1 3A 4 7 23 22 Parts Breakdown Continued 6 Tools Required Ph...

Page 11: ...Not shown 1 10 97 4056 I S ELR Escutcheon Assembly 1 11 650 Top Strike Pack not shown 606 Bottom Strike Pack Fire 12 HC WS not shown 652 Top and Bottom Strike Pack STD not shown 12 52 4922 BIPS 03 Re...

Page 12: ...tal doors 2 Refer to instruction sheet A7971 for rod and inner case installation on wood doors Check hand of door The Multi Point lock may be handed Door should be fitted and hung Verify box label for...

Page 13: ...rface Fig 3A 2 Feed wire through the through hole and attach the outside exit trim to the door A Outside Trim 3 Install Outside Trim and Inside Trim B Inside Trim Fig 3A Outside Exit trim Fig 3B Insid...

Page 14: ...or Fig 5B 2 Align top of reader with top of backplate Pivot reader down until seated Guide wires as needed to avoid pinching 3 Secure the reader with 1 6 32 x 3 8 Phillips or anti tamper security torx...

Page 15: ...and Wire Connections Non ELR 1 Attach mounting plate using 2 8 x 1 2 self drilingl screws Fig 6A 2 Connect 6 and 2 pin connectors from device to 6 and 2 pin connectors on reader harness Fig 6B C 3 Co...

Page 16: ...ening in ELR assembly 3 Slide the mounting clip of the ELR assembly underneath the installed screw and tighten it to secure the assembly in place Note Be careful not to pinch or disconnect the wire lo...

Page 17: ...1 4 Phillips pan head self drilling screws Note For non fire rated doors omit fire plate 8A Position Inside Escutcheon Wires Non ELR 1 Carefully and neatly fold lock body wires onto themselves Electro...

Page 18: ...ified use SARGENT template A7448B to prepare door and frame at desired location 3 Connect the common wire of the switch to the common input terminal of the EAC 4 Connect the normally open wire of the...

Page 19: ...t the product s features and capabilities Wiegand Test Unit If the lock fails to operate when DC voltage is applied A Remove power B Confirm the polarity of the supply i e is positive If the lock is f...

Page 20: ...applications The company s customer base includes commercial construction institutional and industrial markets Copyright 2020 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reser...

Reviews: