Storage Capacity
The Portable Programmer has a memory of 0.5MB.
The portable programmer receives information about the doors forming part of a locking plan. This includes users who will have access to them,
the Timezones in which they will have access, the Calendar of “Public Holidays” etc. Therefore the number of doors that we can transfer to the
Portable Programmer will depend above all on the number of users forming part of the installation.
The following table shows the number of doors to load on the Portable Programmer, depending on the number of users per door:
The number of events that we can retrieve from the doors also depends on the number of events that we have stored on them. The Escutcheons and
Readers can store up to 1,000 events.
If the doors have stored the maximum number of events, we can retrieve events from a maximum of 50 doors in the Portable Programmer.
Portable Programmer Operation
As previously mentioned, the Portable programmer is the link between the management software of the system, installed on the computer, and
the Escutcheons/Readers. Using the Portable Programmer, we can transmit or receive information from the Escutcheons and Readers and carry out
different tasks.
To transmit information to the Escutcheons and Readers the portable programmer must receive that information from the computer. Therefore,
the first thing to do is download the information of the ‘Locking Plan’ of the installation in question to the Portable Programmer. Once we have
downloaded the information, we will be able to carry out tasks further described in this manual.
Transmission of Data to the Portable Programmer
To transmit the ‘Locking Plan’ of the installation to the P.P we connect it to the computer with the RS-232 cable and we switch it on by pressing the
ON/OFF key.
From the PP Menu screen of the TS1000 management software, the ‘Locking Plan’ is downloaded to the P.P by clicking on the button “Send Data to PP”.
4
Lockwood SMARTair
™
Portable Programmer
assaabloy.co.nz
Users/Doors
Doors to load on the PP
50
Up to 1000 doors approx.
100
Up to 500 doors approx.
200
Up to 250 doors approx.
500
Up to 100 doors approx.