1. Rotate the inside rose - first counter clockwise
to seat the threads and then, clockwise to
securely tighten.
2. Slide lever onto spindle until fully
seated. Be sure The H1 reader requires 12VDC
for power. As the lock accepts either 12 or 24V, we
recommend a 12V power supply to support both
the lock and reader with a single power supply. is
horizontal and
facing the hinge side of the door. Push lever
onto spindle so minimum gap is visible.
3. Tighten the set screw securely with
a 1/8” hex wrench.
4. Before closing the door, test that
lever is functional and ensure
smooth operation of the
latchbolt and deadbolt.
Fig. 13A
Fig. 13B
1. Attach front plate with (2) 8-32x1/4” flat head screws
and tighten securely.
Fig. 14A
Set Screw
Inside Lever
Spindle
Inside of Door
(2) 8-32x1/4”
Flat Head Screws
Lock Body Screw
Lock Body Screw
Rose
Outside of Door
14 Attach of Front Plate
13 Install Inside Rose and inside Lever Assembly