1. Rotate the inside rose - first counter clockwise    

    to seat the threads and then, clockwise to  

    securely tighten.
2. Slide lever onto spindle until fully  

    seated. Be sure The H1 reader requires 12VDC 

for power. As the lock accepts either 12 or 24V, we 

recommend a 12V power supply to support both 

the lock and reader with a single power supply. is 

horizontal and  

    facing the hinge side of the door. Push lever  

    onto spindle so minimum gap is visible.
3. Tighten the set screw securely with  

     a 1/8” hex wrench.
4. Before closing the door, test that  

    lever is functional and ensure  

    smooth operation of the  

    latchbolt and deadbolt.

Fig.  13A

Fig. 13B

1. Attach front plate with (2) 8-32x1/4” flat head screws  

    and tighten securely.

Fig.  14A

Set Screw

Inside Lever

Spindle

Inside of Door

(2) 8-32x1/4” 
Flat Head Screws

Lock Body Screw

Lock Body Screw

Rose

Outside of Door

14   Attach of Front Plate

13   Install Inside Rose and inside Lever Assembly

Summary of Contents for Harmony H1

Page 1: ...anufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express written permission of Sargent Manufacturing Company is prohibited HARMONY Mort...

Page 2: ...nce to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Reor...

Page 3: ...A 100 24 20 18 18 16 16 14 12 150 22 18 16 16 14 14 12 10 200 20 18 16 14 14 12 12 10 250 18 16 14 14 12 12 12 10 300 18 16 14 12 12 12 10 400 18 14 12 12 10 10 500 16 14 12 10 10 750 14 12 10 10 1 00...

Page 4: ...of Sargent Manufacturing Company is prohibited 05 15 15 Harmony Series H1 Mortise Lock A7877F 800 810 WIRE 9473 www sargentlock com 4 Tools Required Phillips Screw Driver Standard size Slotted Screw D...

Page 5: ...Adapter Plate And Bushing Assembly Dl 1 12 Reference Harmony Series Catalog For Available Lever Styles 1 13 Reference Harmony Series Catalog For Available Cylinders Size 43 1 14 Lock Body H1 82270 12...

Page 6: ...e www intelligentopenings com Prior to installation make sure all holes are free of burrs debris and sharp edges If doors are not properly reinforced per ANSI 115 2 commercially available reinforcemen...

Page 7: ...t face strike Fig 2B The deadlatch is self adjusting To change hand of latchbolt 1 Insert screwdriver into the spade shaped slot 2 Rotate screwdriver 90 to push latch out until back of latch clears lo...

Page 8: ...n 4 Install appropriate hardware lock body screws NOTE Do not tighten screws completely at this time Cylinder should be installed prior to tightening Inside of Door 2 12 x 1 1 4 Long Flat Head Wood Sc...

Page 9: ...the bottom Remove peel backing and place gasket on door Fig 6 6 Install Inside Gasket if necessary Required for exterior door applications Fig 6 Inside of Door Fig 5B Gasket required for exterior door...

Page 10: ...inder before inserting into the escutcheon Fig 8B 3 Use the key to rotate the cylinder clockwise until it is flush at the bottom and the SARGENT logo is right side up Do not attempt to tighten all the...

Page 11: ...ock body screws Fig 9B Fig 9A Mortise Lock body Screw 8 32 X 5 8 Phillips Oval Head and Lock Washer Machine Screw Mortise Lock body Screw 1 Connect P3 2 pin connector from lock body to J3 on interior...

Page 12: ...g of wires when mounting escutcheon Fig 11B Do not tuck extra mortise lock body wires back inside the lock body cylinder hole Fig 11A Fig 11B Outside of Door 1 Tighten the inside escutcheon securely t...

Page 13: ...the lock accepts either 12 or 24V we recommend a 12V power supply to support both the lock and reader with a single power supply is horizontal and facing the hinge side of the door Push lever onto sp...

Page 14: ...peration Mode 1 Red LED ON when powered Presenting a 125kHz proximity card will cause LED to FLICKER Green and return to Red state Reference Diagram 1 Note LED wire is unconnected Mode 2 Green LED ON...

Page 15: ...COM Blue 6 EGND Brown 7 LED Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 Not Used 12 24VDC H N G 120 VAC Input H1 Harmony Series 12VDC DATA 1 DATA 0 RX RX Electronic Acce...

Page 16: ...anel By Others Use NC for Fail Safe Operation Lock Relay NO Fail Secure Operation READER NEG Black 1 READER POS Red 2 DATA 1 White 3 DATA 0 Green 4 RX NO NC Orange 5 RX COM Blue 6 EGND Brown 7 LED Yel...

Page 17: ...Lock body Power Supply By Others 12 24VDC H N G 120 VAC Input H1 Harmony Series Black Hot White Neutral Green Gnd READER NEG Black 1 READER POS Red 2 DATA 1 White 3 DATA 0 Green 4 RX NO NC Orange 5 RX...

Page 18: ...EADER POS Red 2 DATA 1 White 3 DATA 0 Green 4 RX NO Orange 5 RX COM Blue 6 EGND Brown 7 LED Yellow 8 LOCK NEG Violet 9 LOCK POS Gray 10 DPS NC Pink 11 DPS COM Tan 12 HES 2001M P1 P2 P3 P4 R1 R2 R3 R4...

Page 19: ...ader is ON Red or Green depending on reader configuration See reader LED Configuration 3 Present proximity credential and verify LED and sounder activity 4 Verify valid card read at EAC panel 5 Verify...

Page 20: ...construction institutional and industrial markets Copyright 2015 Sargent Manufacturing Company an ASSA ABLOY Group company All rights reserved Reproduction in whole or in part without the express wri...

Reviews: