16
DIAGRAM #2 – MODE 2: LED WIRE TIED TO GROUND = GREEN LED ‘ON’ WHEN POWERED
Standard Application Shown - For Alternative Applications Contact 1-800-810-WIRE (9473)
*IMPORTANT: Pin 7 must be tied to earth ground in the access control panel.
Failure to follow proper ESD safe grounding procedures could lead to equipment failure.
Typical Harmony Mortise Application Diagram (12/24VDC System)
Black (Hot)
White (Neutral)
Gr
een (Gnd)
12/24VDC
H N G
- +
120 VAC
Input
H1 Harmony Series
(-)
12VDC
(+)
DATA 1
DATA 0
RX
RX
Electronic
Access
Control
Panel
(By Others)
Use (NC) for
Fail Safe
Operation
Lock Relay
(NO) Fail
Secure
Operation
READER NEG - Black, 1
READER POS - Red, 2
DATA 1 - White, 3
DATA 0 - Green, 4
RX (NO/NC) - Orange, 5
RX (COM) - Blue, 6
*EGND- Brown, 7
LED - Yellow, 8
LOCK NEG - Violet, 9
LOCK POS - Gray, 10
DPS (NC) - Pink, 11
DPS (COM) - Tan, 12
DPS
DPS
12 Conductor
ElectroLynx Harness
From McKinney
QC12 Electric
Hinge From
McKinney
Reader Electronics Require 12VDC Filtered and Regulated
Lock body
Power Supply
(By Others)
12/24VDC System
• Reader Draw = 140mA @12VDC
• Actuator Draw = 15mA continuous
• Maximum (2) locks per 1 Amp power supply
(1/2 Amp peak current draw)
This product is polarity sensitive; if the lock does
not operate, check the polarity of the input and
reverse if necessary.
The H1 reader requires
12VDC for power. As the
lock accepts either 12 or
24V, we recommend a 12V
power supply to support
both the lock and reader
with a single power supply.
NOTE:
If your lock is configured with End of Line Resistors,
reference instruction sheet A8191 for the wiring of
RX & DPS outputs.