Egress Monitoring Installation Addendum
Page 1: ...E Plex 5xxx Series Egress Monitoring Installation Addendum ...
Page 2: ...nough to meet the wiring path drilled within the door Do not drill the recessed area completely through the door For metal doors only drill through the outside of the door Do not drill completely through Drill a horizontal hole for the sensor and wires through the edge of the door to intersect with the recessed area 5 1 2 above the latch The horizontal hole size is 3 8 inch diameter and 1 deep for...
Page 3: ... M 295 drill and mount the magnet with the collar provided Caution The magnet is strong Avoid placing the magnet near sensitive devices such as magnetic stripe cards Route the wires through the door It is important to ensure that each wire from the sensor is connected to a wire extending from the lock housing Polarity is not required Insulate the junctions Refer to the Wire Connections at the left...