Kaba’s E-Plex 5900 door lock will monitor opening and closing of
the door. This is accomplished by installing a position sensor in
the door, and installing a permanent magnet in the door frame.
These are shown in the pages that follow.
Installation:
Prepare the door following the E-Plex 5x00 cylindrical lock Installation
Instructions manual. The door surface will be prepared with a 1" diameter
recessed area approximately 1" deep, which will accommodate the sensor
leads to be mounted within the door. The center of this recessed area should
be 5
1
⁄
2
" directly above the center of the 2
1
⁄
8
" hole. A hole is required for the
spindle to pass through the door 2
7
⁄
16
" (2.4”) above the 2
1
⁄
8
" hole. Refer to
the Door and Door Frame Openings illustration below.
For wooden doors, the recessed area must be deep enough to meet the wiring
path drilled within the door. Do not drill the recessed area completely through
the door. For metal doors, only drill through the outside of the door. Do not
drill completely through.
Drill a horizontal hole for the sensor and wires through the edge of the door
to intersect with the recessed area 5
1
⁄
2
" above the latch. The horizontal hole
size is
3
⁄
8
" inch diameter and 1" deep for a tight fit with the sensor. The
remainder should be a
1
⁄
4
" diameter wire path above or below the upper lock
mounting holes.
Caution:
Make sure that the drill path does not interfere with the two upper
1
⁄
4
" lock mounting holes.
Outside lock mounting
surface of door.
6.0"
Sensor
Hole
5.5"
Recessed
Hole
5.4"
Mounting
Hole
2.4"
Spindle
Hole
Wire passage holes intersect,
avoiding two mounting holes.
Align magnet in door frame
with sensor in door.
Wood: .250" dia hole, .375" deep.
Steel: .295" dia hole for
mounting collar.
1" dia recessed
1" deep for wire junction
Pass through hole for small
spindle.
Latch