background image

31

EN

Functions and operation

Signals 

The external door fitting contains a signal LED and a buzzer. The signals and their 
meanings are explained in the following tables. 

Normal operation

There is no fault present in the normal operating mode.

LED signal

Meaning

Door can be opened.

Door cannot be opened.

Door cannot be opened (permanently locked).

10x

Cannot be locked again once released.

 Battery change required

The battery is low or empty (“Replacing the battery”, page 47).

LED signal

Meaning

Battery is very low.
Access is only granted after a waiting period of 
15 seconds and once the door code has been 
entered again. The waiting time is increased to 
60 seconds after 100 on-site inspections. 

Battery is empty.
The door fitting no longer grants access.

Programming mode

The 

ESA500 / ESA501 electronic door

 fitting is in programming mode.

LED signal

Buzzer

Meaning

1x long

Input action required.

3x short

Input action not required.

1x short

Additional inputs required.

125 ms

Touchtone keys: audible beep con-
firms the push of a button.

Tab. 1:

Status messages 

normal operation

green

red

red

red

red

red

red

Tab. 2:

Status messages 

battery

yellow 5 s

yellow

yellow

5 s

red

red

red

5 s

5 s

Tab. 3:

Status messages 

programming 

mode

green

red

orange

Summary of Contents for ESA500

Page 1: ...amming instructions Instructions de programmmation Istruzioni per la programmazione Elektronik T rbeschlag Electronic door fitting Garniture de porte lectronique Bandella elettronica ESA500 ESA501 Pre...

Page 2: ...h tzt Jede Verwertung bzw Ver nderung au erhalb der engen Grenzen des Urheberrechtsgesetzes ist ohne Zustimmung von ASSAABLOYSicherheitstechnikGmbH unzul ssig und strafbar Das gilt insbesondere f r Ve...

Page 3: ...Dauersperren 10 Programmierung 12 bersicht 12 Mastercode 12 Aufrufen und Verlassen des Programmiermodus 12 Einstellen von Funktionen 13 Programmierbeispiel 15 Tabelle der Funktions Codes 16 Technisch...

Page 4: ...em ein berechtigter T r Code eingegeben wird Von innen kann die T r direkt ge ffnet werden der T rdr cker ist dauerhaft aufgekuppelt Der Elektronik T rbeschlag ESA500 bietet Nutzungskategorie 2 nach D...

Page 5: ...nweise ber die Funktion wichtiger Bauteile Bedeutung der Symbole Gefahr Sicherheitshinweis Nichtbeachtung f hrt zu Tod oder schwerer Verletzung Warnung Sicherheitshinweis Nichtbeachtung kann zu Tod od...

Page 6: ...s die LED erloschen ist Wird ein Code drei Mal falsch eingegeben wird das Ger t 30s lang gesperrt Die Sperrzeit verdoppelt sich jeweils nach drei weiteren Fehleingaben des Codes eine Minute zwei Minut...

Page 7: ...edeutung Batterie ist stark verbraucht Zutritt wird erst nach einer Karenzzeit von 15s und erneuter Eingabe des T rcodes gew hrt Nach 100 Begehungen wird die Karenzzeit auf 60s erh ht Batterie ist lee...

Page 8: ...ED gr n T r freigegeben Office Funktion Dauerauf Die Office Funktion entsperrt die T r wahlweise zwischen einer und 36 Stunden oder auf unbestimmte Zeit Office Funktion aktivieren T r Code eingeben 4...

Page 9: ...stellig LED gr n T r freigegeben 2 LED gelb Anzahl Stunden 1 bis 36 eingeben LED 3x gr n T r f r die Anzahl Stunden freigegeben ohne Eingaben begehbar Office Funktion deaktivieren T r Code eingeben 4...

Page 10: ...tercode eingeben Programmiermodus aktiv Programmierung Seite 12 91 1 LED gr n langer Signalton X X X oder 30s warten Dauersperren aktiv Programmiermodus inaktiv Einmalig ffnen ohne Dauersper ren zu de...

Page 11: ...Bedienung Dauersperren deaktivieren 99 Mastercode eingeben Programmiermodus aktiv Programmierung Seite 12 LED blinkt rot 91 0 LED gr n langer Signalton X X X oder 30s warten Dauersperren inaktiv Prog...

Page 12: ...tig konfigurierte Codierung Seite 102 Der Mastercode kann ber eine Programmmierfunktion ge ndert werden Tabelle der Funktions Codes Seite 16 Aufrufen und Verlassen des Programmiermodus Hinweis Program...

Page 13: ...lle der Funktions Codes Seite 16 erfolgt immer nach dem gleichen Muster Abb 1 Abb 2 Abb 1 Eingabe von Funktionen Funktions Code LED gelb Signalton kurz Parameter 1 LED gr n Signalton lang Parameter 2...

Page 14: ...richt 70 Ung ltige Eingaben Wird eine unzul ssige Eingabe get tigt und mit einem best tigt blinkt der Elektronik T rbeschlag einmal rot auf und gibt drei kurze Signalt ne von sich Die Eingabe kann ern...

Page 15: ...T rcode vergeben Programmiermodus einschalten Seite 12 Grunds tzliche Vorgehensweise zur Programmierung Beispiel Eingabe ber Tastatur 99 0123456789 Beschreibung Erkl rung Mastercode Seite 12 und Seite...

Page 16: ...Summer aktiv empfohlen Benutzer Codes programmie ren Dauerfreigabe berechtigung f r einen Benutzer Code ndern Funktionsnr 70 71 72 20 30 Parameter 1 Anzahl Sekunden 3 bis 30 4 4 stellig 6 6 stellig 0...

Page 17: ...T r Code 4 oder 6 Stellen siehe Funktion 71 T r Code 4 oder 6 Stellen siehe Funktion 71 Nummer Spei cherplatz oder T r Code Nummer erster Speicherplatz Bisheriger Mastercode 0 deaktivieren 1 aktiviere...

Page 18: ...ine Entfernung Dr ckerstift 8mm 9mm 10mm T rblattdicke zwischen 40mm und 100mm in Schritten von 10mm Schutzart IP 52 Material Dr ckerstift T rdr cker Montageplatten Abdeckungen Stahl Stahl Stahl Edels...

Page 19: ...N EN 1906 Zulassung f r Feuerschutzt ren nach DIN 18273 Zulassung f r Fluchtwege nach DIN EN 179 ja ja ja Dr ckerversionen U Form Dr ckerstift 9mm T rblattdicke zwischen 40mm und 100mm in Schritten vo...

Page 20: ...cherheitstechnik GmbH Bildstockstra e 20 72458 Albstadt DEUTSCHLAND DoC ESA500 00 2013 EMV Richtlinie 2004 108 EG Elektronischer T rbeschlag ESA 500 Aktualisierte Informationen Aktualisierte Informati...

Page 21: ...ie Lithium CR123A 500ZB BATT 00 Im Lieferumfang des Elektronik T rbeschlages ESA500 ESA501 befindet sich ein Dr ckerstift in einer L nge von 40 bis 100mm Dr ckerstifte in anderen L ngen k nnen separat...

Page 22: ...r ft werden Beachten Sie insbesondere Inspizieren und bet tigen Sie alle Funktionen des Schlosses und des T rbe schlags Stellen Sie so sicher dass alle Teile des Verschlusses Schloss T rbe schlag und...

Page 23: ...n Innent rbeschlag Abb 3 Seite 102 2 Setzen Sie eine neue Batterie ein 3 Befestigen Sie zuerst den Innent rbeschlag dann den Innent rdr cker 4 Pr fen Sie das Schloss auf Leichtg ngigkeit 5 Pr fen Sie...

Page 24: ...os zur ckgegeben werden Sie sind zur R ckgabe gebrauchter Batterien und Akkumulatoren gesetzlich verpflichtet Produkt WEEE Reg Nr DE 69404980 Das Produkt ist nach dem Gebrauch als Elektronikschrott or...

Page 25: ...25 DE...

Page 26: ...hanges outside the strict limits of the copyright are prohibited and liable to prosecution if no prior consent is obtained from ASSA ABLOY Sicherheitstechnik GmbH This particularly applies to any copy...

Page 27: ...Office function always open 32 Permanent lock 34 Programming 36 Overview 36 Master code 36 Entering and exiting the programming mode 36 Setting functions 37 Programming example 39 Table of function c...

Page 28: ...r code The door can be opened directly from the inside the door handle is permanently released The ESA500 offers electronic door fitting Usage category 2 in accordance with DIN EN 1906 Access control...

Page 29: ...ding how key components work Meaning of the symbols Danger Safety warning Failure to observe these warnings will lead to death or serious injury Warning Safety warning Failure to observe these warning...

Page 30: ...ly three times the device is locked for 30seconds The lock out time doubles each time the code is entered incorrectly three times in a row one minute two minutes four minutes etc This is an effective...

Page 31: ...ess is only granted after a waiting period of 15seconds and once the door code has been entered again The waiting time is increased to 60seconds after 100 on site inspections Battery is empty The door...

Page 32: ...digit LED green Door released Office function always open The office function releases the door for between 1 and 36 hours or for an unspecified time Activate office function Enter door code 4 or 6 di...

Page 33: ...6 digit LED green Door released 2 LED yellow Enter number of hours 1 to 36 LED 3x green Door released for the number of hours accessible without input Deactivate office function Enter door code 4 or 6...

Page 34: ...ter master code Programming mode active Programming page 36 91 1 LED green Long signal tone X X X or Wait 30 s Permanent locking active Programming mode inactive Open once without deactivating permane...

Page 35: ...peration Deactivate permanent locking 99 Enter master code Programming mode active Programming page 36 LED blinks red 91 0 LED green Long signal tone X X X or Wait 30 s Permanent locking inactive Prog...

Page 36: ...eady set in the factory page 102 The master code can be changed with a programming function Table of function codes page 40 Entering and exiting the programming mode Note Exit programming mode automat...

Page 37: ...age 40 are always entered according to the same formula Fig 1 Fig 2 Fig 1 Entry of functions Function code LED yellow Signal tone short Parameter 1 LED green Signal tone long Parameter 2 Optional LED...

Page 38: ...s to 70 Invalid entries If an impermissible entry is made and confirmed with the electronic door fitting will flash red once and three brief signals will sound The entry can be carried out again Examp...

Page 39: ...or code Basic procedure for programming Example Input via key pad 99 0123456789 Description explanation Master code page 36 and page 102 Switch on programming mode page 36 Select function page 37 20 F...

Page 40: ...ve recommend ed Program user codes user code Change permanent release authorization for a user code Functionsno 70 71 72 20 30 Parameter 1 Number of seconds 3 to 30 4 4 digit 6 6 digit 0 deactivate 1...

Page 41: ...or code Door code 4 or 6 digits see Function 71 Door code Door code 4 or 6 digits see Function 71 Number mem ory space for door code Number of first memory space Previous mas ter code 0 deactivate 1 a...

Page 42: ...cover No distance Handle pin 8mm 9mm 10mm Door leaf thickness between 40mm and 100mm in increments of 10mm Protection rating IP 52 Material Handle pin Door handle Mounting plates Covers Steel Steel S...

Page 43: ...proval for fire doors in accordance with DIN 18273 Approval for escape routes in accordance with DIN EN 179 Yes Yes Yes Handle versions U shaped Handle pin 9mm Door leaf thickness between 40mm and 100...

Page 44: ...ABLOY Sicherheitstechnik GmbH Bildstockstra e 20 72458 Albstadt GERMANY DoC ESA500 00 2013 EMC directive 2004 108 EC ESA 500 electronic door fitting Updated information Updated information is availab...

Page 45: ...al page 48 CR123A lithium battery 500ZB BATT 00 The ESA500 ESA501 electronic door fitting is supplied with a handle pin 40 to 100mm in length Handle pins with different lengths can be ordered separate...

Page 46: ...s days is lost Fire doors must be checked for correct and safe function at intervals of no longer than one month In particular Inspect and confirm all functions of the lock and the door fitting Ensure...

Page 47: ...n the internal door fitting Fig 3 page 102 2 Insert a new battery 3 Fix the internal door fitting first of all followed by the internal door handle 4 Check the lock for ease of movement 5 Check all fu...

Page 48: ...u are legally obliged to recycle used batteries Product WEEE reg no DE 69404980 You must dispose of the product correctly as electronic scrap after use and take it to a local collection point for recy...

Page 49: ...49 EN...

Page 50: ...es du cadre d usage conforme pr vu par la loi sur les droits d auteur sont interdites et passibles de peine sans autorisation pr alable de la soci t ASSA ABLOY Sicherheitstechnik GmbH Ceci est particu...

Page 51: ...Office ouverture permanente 56 Blocage permanent 58 Programmation 60 Aper u 60 Code ma tre 60 Appeler et quitter le mode de programmation 60 R glage de fonctions 61 Exemple de programmation 63 Tableau...

Page 52: ...t rieur elle peut tre ouverte directement par l interm diaire de la b quille qui est embray e en permanence La garniture de porte lectronique ESA500 offre cat gorie d utilisation 2 selon la norme DIN...

Page 53: ...ants Signification des pictogrammes Danger Consigne de s curit le non respect de cette mise en garde implique un risque mortel ou de blessures graves Avertissement Consigne de s curit le non respect d...

Page 54: ...reil se bloque pendant 30 s La dur e de blocage double chaque nouvelle s rie de trois entr es incorrectes du code une minute deux minutes quatre minutes et ainsi de suite ce qui est tr s efficace cont...

Page 55: ...ineux Signification Pile tr s us e L acc s est nouveau possible apr s un d lai d at tente de 15 s et une nouvelle entr e du code Apr s 100 cycles d acc s le d lai d attente monte 60 s La pile est vide...

Page 56: ...ce ouverture permanente La fonction Office peut tre param tr e de mani re ce que la porte soit d bloqu e pour une dur e entre 1 et 36 heures ou encore pour une dur e ind termin e Activer la fonction O...

Page 57: ...erte Porte d verrouill e 2 LED jaune Saisir le nombre d heures 1 36 LED 3 x vert Porte d verrouill e pendant un certain nombre d heures ouverte sans saisie de code D sactiver la fonction Office Entrer...

Page 58: ...ode programmation actif Programmation page 60 91 1 LED verte Signal sonore long X X X ou patienter 30 s Blocage permanent activ Mode programmation inactif Effectuer une ouverture unique sans d sactive...

Page 59: ...activer le blocage permanent 99 Saisir le code ma tre Mode programmation actif Programmation page 60 LED rouge clignotante 91 0 LED verte Signal sonore long X X X ou patienter 30 s Blocage permanent i...

Page 60: ...peut tre modifi l aide d une fonction de programmation Tableau des codes de fonctions page 64 Appeler et quitter le mode de programmation Avis Quitter automatiquement le mode de programmation La d sa...

Page 61: ...des codes de fonctions page 64 est toujours identique Fig 1 Fig 2 Fig 1 Entr e de fonctions Code de fonctions LED jaune Signal sonore bref Param tre 1 LED verte Signal sonore long Param tre 2 En opti...

Page 62: ...Entr es invalides En cas de saisie d une entr e invalide suivie d une confirmation avec la garniture lectronique clignote une fois en rouge en mettant trois signaux sonores brefs Une nouvelle entr e...

Page 63: ...ode de programmation page 60 Proc dure fondamentale pour la programmation Exemple Entr e l aide du clavier 99 0123456789 Description Explication Code ma tre page 60 et page 102 S lectionner une foncti...

Page 64: ...r actif recommand Programmer le code utilisateur Modifier une autorisation de lib ration permanente d un code d utilisateur n de fonction 70 71 72 20 30 Param tre 1 Nombre de secondes 3 30 4 4 caract...

Page 65: ...u 6 ca ract res voir fonction 71 Code porte 4 ou 6 ca ract res voir fonction 71 Num ro d em placement de m moire ou code Num ro du premier em placement de m moire Ancien code ma tre 0 d sactiver 1 act...

Page 66: ...orgne pas d entraxe Carr 8mm 9mm 10mm paisseur du vantail de porte entre 40mm et 100mm par pas de 10 mm Indice de protection IP 52 Mat riau Carr B quille Plaques de montage Caches Acier Acier Acier Ac...

Page 67: ...tes coupe feu selon DIN EN 18273 Homologation pour portes de secours selon DIN EN 179 Oui Oui Oui Versions de b quilles forme U Carr 9mm paisseur du vantail de porte entre 40mm et 100mm par pas de 5mm...

Page 68: ...Y Sicherheitstechnik GmbH Bildstockstra e 20 72458 Albstadt ALLEMAGNE DoC ESA500 00 2013 Directive CEM 2004 108 CE Garniture de porte lectronique ESA 500 Informations actualis es Vous trouverez les in...

Page 69: ...72 Pile lithium CR123A 500ZB BATT 00 Un carr d une longueur de 40 100 mm est compris dans la livraison de la garniture de porte lectronique ESA500 ESA501 Des carr s d une autre longueur peuvent tre co...

Page 70: ...e dur e maximale d un mois Portez une attention particuli re aux points suivants Inspectez et actionnez toutes les fonctions de la serrure et de la garniture V rifiez ainsi que tous les l ments du sys...

Page 71: ...t rieure Fig 3 page 102 2 Ins rez une nouvelle pile 3 Fixez d abord la garniture int rieure et ensuite la b quille int rieure 4 Contr lez la souplesse de fonctionnement de la serrure 5 Contr lez toute...

Page 72: ...lecte local Selon la loi vous tes tenu de rapporter les piles et accumulateurs usag s un centre de collecte Produit N d enr DEEE DE 69404980 Lorsqu il est usag le produit doit tre limin correctement e...

Page 73: ...73 FR...

Page 74: ...za previa autorizzazione di ASSA ABLOY Sicherheitstechnik GmbH costituisce un illecito ed punibile secondo la legge Quanto sopra vale in particolare per le riproduzioni le traduzioni e le registrazion...

Page 75: ...one office sempre aperto 80 Sempre chiuso 82 Programmazione 84 Sommario 84 Codice master 84 Attivazione disattivazione della modalit di programmazione 84 Impostazione delle funzioni 85 Esempio di prog...

Page 76: ...a maniglia sempre inserita Caratteristiche della bandella elettronica ESA500 Categoria di utilizzo 3 a norma DIN EN 1906 Controllo degli accessi tramite codici di apertura porta Codici di apertura por...

Page 77: ...i importanti Significato dei simboli Pericolo Indicazione di sicurezza La mancata osservanza di tale indicazione comporta il decesso o gravi lesioni Avvertenza Indicazione di sicurezza La mancata osse...

Page 78: ...olte un codice di apertura sbagliato si genera un tempo di attesa di 30 secondi Per ogni successiva immissione di un codice utente sbagliato si raddoppia il tempo di attesa 1 minuto 2 minuti 4 minuti...

Page 79: ...carsi L accesso consentito solo dopo aver immesso di nuovo il codice di apertura al termine del periodo di tolleranza di 15secondi Dopo 100 attivazioni il periodo di tolleranza passa a 60 secondi La b...

Page 80: ...ione office sempre aperto La funzione office sblocca per un periodo di tempo a scelta tra 1 e 36 ore o per un periodo di tempo indeterminato Attivazione della funzione office Immettere il codice di ap...

Page 81: ...lo Immettere il numero di ore da 1 a 36 LED 3 volte verde Porta sbloccata per il numero di ore immesse ovvero accessibile senza dover immettere il codice di apertura Disattivazione della funzione offi...

Page 82: ...ster Modalit di programmazione attiva pagina 83 91 1 LED verde Bip lungo X X X oppure attendere 30s Sempre chiuso funzione attiva Modalit di programmazione disattiva Apertura unica senza disattivare i...

Page 83: ...one del sempre chiuso 99 Immissione del codice master Modalit di programmazione attiva pagina 83 LED lampeggia di luce rossa 91 0 LED verde Bip lungo X X X oppure attendere 30s Sempre chiuso inattivo...

Page 84: ...tramite la funzione di programmazione Tabella dei codici funzione pagina 88 Attivazione disattivazione della modalit di programmazione Avviso Disattivazione automatica della modalit di programmazione...

Page 85: ...i Tabella dei codici funzione pagina 88 avviene sempre secondo la stessa procedura Fig 1 Fig 2 Fig 1 Immissione di funzioni codice funzione LED giallo Bip breve parametro 1 LED verde Bip lungo paramet...

Page 86: ...corrisponde a 70 Immissione non valida In caso di immissione invalida confermata con un il LED della bandella elettronica lampeggia una volta di luce rossa ed emette 3 bip brevi possibile eseguire di...

Page 87: ...modalit di programma zione pagina 84 Procedura di base per la programmazione Esempio immissione tra mite tastiera 99 0123456789 Descrizione spiegazione Codice master pagina 84 e pagina 102 Selezione...

Page 88: ...tivo consigliato Programmazio ne dei codici utente Modifica dell autorizza zione allo sblocco perma nente per un codice utente N funzione 70 71 72 20 30 Parametro 1 N di secondi da 3 a 30 4 a 4 cifre...

Page 89: ...apertura a 4 o 6 cifre vedi funzione 71 Codice di apertura a 4 o 6 cifre vedi funzione 71 Numero di posizione di memoria o codice di apertura N della prima posizione di memoria Codice master esistent...

Page 90: ...distanza Perno maniglia 8mm 9mm 10mm Spessore pannello porta tra 40e 100mm con incrementi di 10 mm Grado di protezione IP 52 Materiale Perno maniglia Maniglia porta Piastra di montaggio Coperture acc...

Page 91: ...ta gliafuoco ai sensi della normativa DIN EN 18273 Omologazione per porte di uscite di emergenza ai sensi della norma tiva DIN EN 179 s s s Versioni maniglia Forma a U Perno maniglia 9mm Spessore pan...

Page 92: ...OY Sicherheitstechnik GmbH Bildstockstra e 20 72458 Albstadt GERMANIA DoC ESA500 00 2013 Direttiva EMC 2004 108 CE Bandella elettronica ESA 500 Informazioni aggiornate Per informazioni aggiornate cons...

Page 93: ...96 Batteria al litio CR123A 500ZB BATT 00 La dotazione della bandella elettronica ESA500 ESA501 comprende un perno maniglia lungo da 40 a 100mm Perni di maniglia di altre lunghezza vanno ordinati a p...

Page 94: ...eguenti operazioni Ispezionare e azionare tutte le funzioni della serratura e della bandella Accer tarsi che tutte le parti della chiusura serratura bandella e frontale funzionino correttamente Accert...

Page 95: ...a porta e quindi la bandella Fig 3 pagina 102 2 Inserire la nuova batteria 3 Montare la bandella sul lato interno della porta e quindi la maniglia 4 Controllare che la serratura funzioni dolcemente 5...

Page 96: ...locale per lo smaltimento La legge obbliga l utente a restituire le batterie esauste e gli accumulatori usati Prodotto N reg WEEE DE 69404980 Dopo l utilizzo il prodotto va smaltito come rifiuto elett...

Page 97: ...97 IT...

Page 98: ...cherten Codes Table of the saved codes Tableau des codes m moris s Tabella dei codici salvati DE EN FR IT Nr No N N Code 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 Nr No N N Code 23 24 2...

Page 99: ...99 D E E N F R I T DE EN FR IT Nr No N N Code Nr No N N Code...

Page 100: ...100 D E E N F R I T DE EN FR IT...

Page 101: ...101 D E E N F R I T DE EN FR IT...

Page 102: ...ery and fix internal door handle Fig 3 Mettre en place la pile et fixer la b quille int rieure Fig 3 Inserire la batteria e fissare la maniglia interna Werkseitig konfigurierte Codierung Coding config...

Page 103: ...103 D E E N F R I T DE EN FR IT...

Page 104: ...7431 123 0 Fax 49 7431 123 240 albstadt assaabloy com www assaabloyopeningsolutions de Die ASSA ABLOY Gruppe ist der Weltmarktf hrer in Zugangsl sungen Jeden Tag helfen wir Menschen sich sicherer und...

Reviews: