50
EN
Installation
Mount the electric security lock 809M
1 Screw
the
electric security lock 809M
into place in the lock pocket.
2
Fasten the lock escutcheons.
3 Test
the
electric security lock 809M
for ease of movement.
The
electric security lock 809M
is ready for operation with the mounted striking plate.
Mounting the striking plate
1
Finish the striking pocket and all drilled holes (“Solid leaf striking plate“, page 56 and “High-security
striking plate“, page 59).
2
Clean the striking plate pocket and all drilled holes by blowing them out or vacuuming.
3
Screw the matching locking into place for the
electric security lock 809M
to be installed.
4 Test
the
electric security lock 809M
for ease of movement.
The
electric security lock 809M
is ready for operation.
Mounting escutcheons and locking cylinders
1
Remount the escutcheons.
2 Place
the lock cylinder in, and keep in mind that the cylinder’s locking nose is in the middle position (Pic. 10).
3
Fix the locking cylinder into place with the Cylinder fixing screw.
The
electric security lock 809M
is now fully mounted.
Testing the electric security lock 809M
1
Test all functions of the
electric security lock 809M
.
2
Check whether the latch and auxiliary latch bolt of the lock are pushed back by the same impact edge.
3
Check whether all bolts can freely extend and retract without transverse shear stress after installation (Pic. 7).
The
electric security lock 809M
is fully mounted and tested for functionality.
Pic. 7 :
No transverse shear
stress on the bolt after
installation
F
Q
= 0 N
F
Q
= 0 N
min. 2
min. 2
Striking plate
Face plate
Screw in electric security
bolt
Screw in the matching
striking plate
Fix the locking cylinder
with cylinder fixing
screw
Check for complete
functionality