background image

17

FM437 11/18

Copyright © 2018, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or 
in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.

For installation assistance contact Corbin Russwin 
1-800-543-3658 • [email protected]

MP9800 Series 

Access 600 Integrated Wiegand

with and without MELR Option (Electric Latch Retraction)

Installation Instructions

Multi-Point Lock

11

Installation continued

Inside of 

Door

8-32 x 3/8" 
Phillips Flat Head 
Undercut Combo 
Screw

P4

P3

3.  Twist into place, perpendicular with 

door. (Figure 22)

4.  Position green/yellow ground wire ring 

terminal (from lockbody) over hole for 
top left screw. (Figure 22)

5.  Position green/yellow reader harness 

earth ground on top of ground ring 
and thread both with one (1) 8-32 x 
3/8" Phillips flat head undercut combo 
screw. (Figure 23) 
 

IMPORTANT: Note orientation of 
ground ring terminals. 

6.  Tighten securely.

Connector Attachment 
(Exterior PCB Assembly)

1. Connect P3 (2-pin connector) from 

lockbody to J3 on module. (Figure 24)

2. Connect P4 (6-pin connector) from 

lockbody to J4 on module. (Figure 24)

N. Position inside escutcheon and wires. 

(MELR) M802 or M812

1.  Position escutcheon against door by 

hooking top edge on top of MELR 
assembly. Verify that no wires are 
being pinched. 

2.  Mount inside escutcheon assembly 

to plate using one (1) #8-32 x 5/8" 
Phillips flat head undercut machine 
screw. (Figure 25) 

Figure 22 

Figure 23 

Figure 24 

Figure 25 

M802 MELR

M812 MELR

Summary of Contents for Corbin Russwin MP9800 Series

Page 1: ...own to the state of California to cause cancer and birth defects or other reproductive harm For more information go to www P65warnings ca gov Ce produit peut vous exposer au plomb qui dans l tat de la...

Page 2: ...ssistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com 1 3 2 4 TOC Table of Contents Warnings 3 General Description 3 Features 4 Regulatory Specifications 4 Wiring Dia...

Page 3: ...nly signifies that Industry Canada technical specifications were met This Class B digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subje...

Page 4: ...ush 15mA continuous Total System Draw 525mA 12VDC System MELR Reader Draw 150mA 12VDC MELR Module Draw 850mA Total System Draw 1 Amp Reader Draw 125mA 12VDC MELR Module Draw 850mA Total System Draw 97...

Page 5: ...n wire or door reader performance will be impacted PIN 8 Yellow LED PIN 6 Blue RX COM PIN 4 Green Data 0 PIN 2 Red Reader POS PIN 1 Black Reader NEG PIN 3 White Data 1 PIN 5 Orange RX NO PIN 7 Brown E...

Page 6: ...tion Lock Relay Fail NO Secure Operation DPS DPS Black Hot White Neutral Green Gnd Door Position Switch 12 Conductor ElectroLynx Harness From McKinney QC12 Electric Hinge From McKinney Lockbody Power...

Page 7: ...9800 Series Access 600 Integrated Wiegand with and without MELR Option Electric Latch Retraction Installation Instructions Multi Point Lock 7 Access 600 Series M802 MP9800 Series Inside Trim Assembly...

Page 8: ...ccess and Egress Hardware Group Inc is prohibited For installation assistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com 8 Access 600 Series M812 MP9800 Series Top C...

Page 9: ...eries Access 600 Integrated Wiegand with and without MELR Option Electric Latch Retraction Installation Instructions Multi Point Lock 9 Access 600 Series M802 MELR Add on Top Case Assembly Metal Door...

Page 10: ...ardware Group Inc is prohibited For installation assistance contact Corbin Russwin 1 800 543 3658 techsupport corbinrusswin assaabloy com 10 Access 600 Series M812 MELR Add on Top Case Assembly Metal...

Page 11: ...prepare door according to appropriate template Refer to templates at corbinrusswin com Figure 2 Metal door Steel MPAD FM438 Templates T31242 Wood door MPWD FM436 Templates T31243 Note For MELR door pr...

Page 12: ...l inside mounting plate on multi point lock with MELR 1 Prepare MELR mounting holes if required IMPORTANT If manufacturer has not pre drilled door prepare door per instructions below using plastic tem...

Page 13: ...elf tapping wood screw for wood doors Figure 11 NOTE Leave screw loose enough to slide MELR assembly on 2 Snake wire through MELR assembly 3 Slide mounting bracket of MELR assembly underneath installe...

Page 14: ...m inside trim to top left screw Figure 15 I Connect Electrolynx harness for Access 600 x M802 NOTE If installing an Access 600 M812 proceed to step K 1 Connect P3 2 pin connector from lockbody or MELR...

Page 15: ...assembly to prevent any damage caused by pinching wires 1 Align ElectroLynx connectors 8 and 4 pin to one side of wire guide inside of door Reader connections and excess wire are arranged on other sid...

Page 16: ...pin from door to interior PCB assembly Figure 20 NOTES Neatly fold wires into remaining space to prevent pinching wires when mounting escutcheon Do not tuck extra mortise lockbody wires back inside lo...

Page 17: ...ellow ground wire ring terminal from lockbody over hole for top left screw Figure 22 5 Position green yellow reader harness earth ground on top of ground ring and thread both with one 1 8 32 x 3 8 Phi...

Page 18: ...is product System integrator shall determine use and installation location 2 Drill a 1 diameter hole for both magnet and switch Both holes shall be 1 deep and for switch if needed drill a 1 4 hole for...

Page 19: ...ty credential and verify LED and sounder activity 4 Verify valid card read at EAC Panel 5 Verify system operation functions i e when credential is presented to reader that door unlocks Figure 27 Featu...

Page 20: ...re Group Inc All rights reserved Reproduction in whole or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group Inc is prohibited Corbin Russwin 225 Episcopal R...

Reviews: