Installation continued
L. Connect ElectroLynx harness.
(For Access 600 x M812)
1. Connect P5 (7 Pin Connector) from reader
board to J5 on interior escutcheon PCB
assembly. (Figure 20)
2. Connect ElectroLynx harness (4 and 8-pin)
from door to interior PCB assembly.
(Figure 20)
NOTES:
• Neatly fold wires into remaining space to
prevent pinching wires when mounting
escutcheon.
• Do not tuck extra mortise lockbody wires
back inside lockbody cylinder hole.
• Connectors attach properly in only one
orientation.
• Do not offset connector.
• Be sure connection is secure by gently
tugging on wire.
J1
J2
P5
8-pin
ElectroLynx
4-pin
ElectroLynx
PCB Layout - Wire Assignments - ElectroLynx Assembly (Molex)
J2
J1
1-Violet Lock Neg
Actuator (+)
Solenoid (-)
3-Pink
-
1- Black
PWR NEG
3-White
DATA 1
5-Orange
RX (NO)
7-Brown
EGND
2-Gray Lock Pos
Actuator (+)
Solenoid (-)
4-Tan
-
2-Red
PWR POS
4-Green
DATA 0
6-Blue
RX (COM)
8-Yellow
LED
Figure 20
M. Install controller.
(For Access 600 x M812)
1. Once wires are arranged, position
controller at a rotated angle against
door, under earth ground wire.
2. Press piece against door while turning
clockwise. (Figure 21)
Rotate Clockwise
Figure 21