ED5800 (A) Series
Installation Instructions
Concealed Vertical Rod Exit Devices
FM171 01/19
Copyright © 2012, 2019, ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole
or in part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
10
Bolt
Engagement
Shim
Strike
Roller
Bolt
Tripping
Lever
B2
C1
B1
Top Adjusting Screw
Bottom Adjusting Screw
A
C2
SHORTER (CCW)
LONGER (CW)
TOP ROD
SHORTER (CCW)
LONGER (CW)
BOTTOM ROD
12
Complete Installation Continued
Figure 22
3. Adjust bottom rod with adjusting
screw C2. (Figure 22) With top latch
retracted in hold back position, and
touchbar dogged or fully depressed,
adjust bottom rod so deadbolt
clears strike by 1/16" (1.6). Bottom
rod should be in position in active
case with square head of connector
hanging in Guide. (See note in Step
2).
4. Check device operation by opening
and closing door. An additional
minor adjustment may be required
for full retraction and correct strike
engagement.
NOTE: To avoid thread damage and
provide positive locking, be sure set
screws engage flats on adjusting
screws.
C. After acceptable device function, install
third screw in top strike to lock strike in
position with 10-24 x 3/4" PFHMS.
D. Install device cover and end cap with
two (2) 8-32 PFHMS each.