background image

P

rogramming Guide

®

For use with 

IQ KP* only

IQ PROX

Series

Summary of Contents for i Que PROX Series

Page 1: ...P r o g r a m m i n g G u i d e For use with IQ KP only IQ PROX Series ...

Page 2: ...ystem Please take the time to read it thoroughly and follow the instructions carefully so that your experience will be positive and trouble free Marks USA would like to thank you for selecting the i Que series for your access control needs For Technical Support Contact Marks USA 5300 New Horizons Blvd Amityville NY 11701 LIVE TECH REP 8 AM 8 PM EST Mon Fri Call 1 800 526 0233 In NY 1 631 225 5400 ...

Page 3: ...nction 39 Master 03 Page 7 Section 3 Scheduling Overview Page 8 Set Time Function 12 Master 03 Page 8 Set Date Function 13 Grand Master 02 Page 9 Basic Schedule Function 02 Master 03 Page 9 Group Schedule Function 03 Master 03 Page 9 User Schedule Function 04 Master 03 Page 10 Passage Schedule Function 05 Master 03 Page 10 Temporary User Schedule Function 06 Master 03 Page 10 Holiday Maintenance F...

Page 4: ...CODE Can also open the lock 8 SYSTEM MANAGER Person establishing the GGM and responsible for highest level of programming Can establish lower levels of programming for other users or groups 9 PROGRAM INSTRUCTION Series of key strokes used to enter a function IMPORTANT KEYS 1 TERMINATOR KEY Acts like the Enter key on a computer and is used to add or confirm codes on the keypad 2 PROGRAMMING KEY Aft...

Page 5: ...s now established for the SYSTEM MANAGER only Enter the UID followed by the PROX to test the lock access Lock is now initialized SYSTEM MANAGER S ACCESS TO THE LOCK Enter UID plus key PROX card SYSTEM MANAGER S ENTRY TO PROGRAMMING MODE Enter UID plus key PROX card In addition to the use of the PROX card to program or access the lock the keypad may be used as an alternate method to accomplish thos...

Page 6: ...n GROUP 09 will automatically put lock into passage or locked mode each time their YOUR CODE is entered GROUPS 10 through 99 have no programming rights Their access may be restricted by schedules or during holidays They may however change their own PIN when authorized by the SYSTEM MANAGER Function 01 Adding Deleting User Codes Min Group Number 03 To Add Users Enter UID the key PROX card FUNCTION ...

Page 7: ...s Min Group Number 03 This function is used to temporarily deny access to User Groups 10 99 without removing them from the memory To DENY access to a Group To RESTORE access to a Group Function 07 Change Group Association Min Group Number 03 This function allows management to change the Group an existing User is assigned to PROGRAM INSTRUCTION UID PROX 07 User UID of existing User New Group No PRO...

Page 8: ... set from 1 to 9 seconds Default setting is 3 seconds Function 33 Multiple Code Entry Min Group Number 03 For higher security the lock can be set to require two User codes be entered before access is granted For even higher security it can be required for one of the Users to be in a Manager Group One User code required Default Two User codes required Two User codes one must be a Manager Three Code...

Page 9: ...audio is turned off default Audio Off Default Audio On Function 36 Fail Safe Fail Secure Min Group Number 03 Use this function to create a power reserve to ensure if the Low Battery Warning is not heeded and the battery pack fails the lock will fail in the selected state Lock fails in the last state that the lock was in when the power was lost Default Fail Safe Lock will ensure that power is reser...

Page 10: ...ode This is a factory installed option If you have purchased this option it must be enabled after the lock is initialized The privacy mode option includes a button installed on the inside housing When pressed it will block out keypad entries except the GGM GM and Master codes When the inside lever is turned the request to exit switch will reset the keypad back to normal operating mode Privacy Mode...

Page 11: ...day 01 08 Week days Monday through Friday 09 Week ends Sat Sun 10 Even Days Tuesday Thursday 11 Odd Days Monday Wednesday Friday 12 Override Preprogrammed Holidays Used when a holiday is scheduled but a certain User Group needs access 13 All Days Open and Close times Use the 24 hour Military Time format for entering Start and End times for schedules The chart below shows the 24 hour format Functio...

Page 12: ... Schedule cannot be used with the Group Schedule 03 or User Schedules 04 NOTE Time must be entered in Military Time format Day Codes 01 07 Individual days of the week ex Monday 01 08 Week days Monday through Friday 09 Week Ends Sat Sun 10 Even Days Tuesday Thursday 11 Odd Days Monday Wednesday Friday 13 All Days Function 03 Group Schedule Min Group Number 03 This schedule will apply to all the Use...

Page 13: ...ime must be entered in Military Time format NOTE If needed Manual Passage Mode Function 30 page 6 or a User assigned to Group 9 will override this schedule until midnight of the same day Day Codes 01 07 Individual days of the week ex Monday 01 08 Week days Monday through Friday 09 Week Ends Sat Sun 10 Even Days Tuesday Thursday 11 Odd Days Monday Wednesday Friday 13 All Days Function 06 Temporary ...

Page 14: ...eadjusted each year Also You may enter a shutdown as one event by entering the start date and end date Example Christmas New Year week Start 1225 End 0101 is an eight day period To SET a Holiday To DELETE ALL set Holidays Function 31 First Supervisor To Arrive Min Group Number 03 When enabled this function will delay the set schedules until a manager has entered his code Users In Groups 10 99 will...

Page 15: ...ng the i Que page 14 Delete ONLY Schedules and Holidays Function 17 Battery Status Check Min Group Number 03 This function manually checks the battery status of the i Que The LED on the keypad will display visual indicator Green Green Two green LED flashes indicate full power 5 25 volts and above Yellow Yellow Two yellow LED flashes 5 25 to 4 75 volts Yellow Red Yellow then Red LED flashes 4 75 to...

Page 16: ... gradual curve in the drop off voltage This curve determines the power settings for the two stages of battery warnings and the Fail Secure settings A lithium battery differs from an alkaline battery in the life cycle of the battery cell A lithium battery has a very sharp drop off voltage going from fully charged to a dead cell quickly This makes monitoring the voltage settings impossible Two Stage...

Page 17: ... set amount of time button not included Reset Key Switch Black And Yellow factory Installed option This option will monitor if a key is used to open the lock For Resetting the i Que see below Motor cable Red and Gray lines to the motor connector Power RED and Black 6 Volts DC Connects to the supplied battery pack Panic Alarm Green and Black hard wired to an alarm device When function 38 is enabled...

Page 18: ...ed human eye Keypad A device for inputting information into a computer controlled system for the purposes of arming and disarming an alarm system or operating an access control system Multiple Key The pressing of more than one key simultaneously Depressions Tailgating In access control tailgating is the act of one or more individuals entering a controlled area by using a single card or code Also k...

Page 19: ...Only Entry 4 Function 33 Multiple Code Entry 5 Function 34 Lock Audio 6 Function 36 Fail Safe Fail Secure 6 Function 38 Panic Alarm 7 Function 39 Privacy Mode 7 G GGM Code 1 Group Association Change Function 07 4 Group Numbers 3 Group Security Levels 3 Group Schedule Function 03 9 H Holiday Maintenance Function 09 11 I Initialize Lock ID 2 Initialize Great Grand Master 2 K Keypad Information 1 M M...

Page 20: ...b at for information on additional product lines templates and manuals For IQ Tech Support Call 1 800 526 0233 LIVE TECH SUPPORT 8am to 8pm EST Mon Fri On Line Tech Support 24 7 at www marksusa com Email ique marksusa com Distributed by ...

Reviews: