11
ED3400/ED3400A Series
Installation Instructions
Surface Vertical Rod
FM361 04/20
Copyright © 2020 ASSA ABLOY Access and Egress Hardware Group, Inc. All rights reserved. Reproduction in whole or in
part without the express written permission of ASSA ABLOY Access and Egress Hardware Group, Inc. is prohibited.
For installation assistance contact Corbin Russwin
1-800-543-3658 • [email protected]
l
Rod Guides
1. Insert top and bottom rod guides at
center of each rod and secure.
2. Test to confirm that rods move
smoothly in rod guide and do not bind.
If not, loosen screws slightly.
#10-24 x 1-1/4"
Phillips Oval
Head (Total = 4)
Rod Guide Mounting Screws - Actual Size
Rod Guide Mounting Screws - Actual Size
Wood: #8 x 1-3/4"
Phillips Oval Head
Screw (Total = 4)
Figure 27
m
Crossbar
1. Slide crossbar into active chassis arm.
2. Slide crossbar into inactive chassis arm.
3. Insert plugs and secure to bar with locking screws.
4. Depress the crossbar to confirm the latchbolts retract and the
top latch goes into latch holdback.
5. Test top latch trigger to confirm rods drop when door closes.
#10-24 x 3/4" Socket Head
Cap Screw (Total = 2)
Crossbar Mounting Screws - Actual Size
Figure 29
n
Top Latch Trigger
Press down on top latch trigger to confirm latchbolt and rods retract.
Rod guide
Rod guide
Bottom rod
Top rod
Figure 26
Locking screw
Crossbar
Plug
Arm
Figure 28
Top latch trigger
Figure 30