Service/Maintenance

As mentioned earlier in this manual, service and adjustments performed by your ASSA ABLOY Entrance
Systems-authorized representative will ensure safe and proper operation of your automatic door
unit.
Remember to keep “Service Log Book” and “Site Acceptance Test and Risk Assessment” documents
(PRA-0007) available. These are used together.
The table below shows the recommended interval in months, when to replace parts during preventive
maintenance. Talk to your ASSA ABLOY Entrance Systems representative to learn more about our
service offering.

Abusive
Environ-
ment

Cycles/hour in operation

Part number

Part

>100

<100

<10

High
traffic

Medium
traffic

Low
traffic

6

6

12

24

330000271 SI/BK

PUSH arm service kit

6

6

12

24

330000272 SI/BK

PULL arm service kit

6

6

12

24

330000276

Stop arm kit

6

6

12

24

330000275

Micro switch kit

6

6

12

24

330000270 SI/BK

Adaptor kit

60

60

60

60

331007291

Transmission unit

60

60

60

60

331008346

Control unit CU-200 with EXU-
boards

24

24

24

24

33738753

Battery

Other products from ASSA ABLOY Entrance Systems

Door Systems

Balance doors

Air curtains

Revolving doors

Sliding doors

Automatic and manual activation units

Service such as preventive maintenance and upgrade programs, emergency repairs, service advice
and door management

1009729-EI-2.0

Issue 2013-12-18

12

Summary of Contents for Besam SW200i

Page 1: ...Swing Door Operator Besam SW200i User Manual Original instructions ASSA ABLOY the global leader in door opening solutions...

Page 2: ...ting 12 Service Maintenance 12 Other products from ASSA ABLOY Entrance Systems 13 Declaration of conformity All rights in and to this material are the sole property of ASSA ABLOY Entrance Systems AB C...

Page 3: ...sons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given supervision or instruction by a person responsible for their safety concerning saf...

Page 4: ...ception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one or more of the following measures Re orient the receiving antenna R...

Page 5: ...irectly byacircumstancebeyondthecontroloftheapplicable company within ASSA ABLOY Entrance Systems such as industrial dispute fire natural disaster war extensive military mobilization insurrection requ...

Page 6: ...ut shaft by a combination of a bevel gear and spur gears The arm system that is connected to the output shaft opens the door in a wall mounted application There is also an adjustable spring mechanism...

Page 7: ...pecification ASSA ABLOY Entrance Systems AB Manufacturer Lodjursgatan 10 SE 261 44 Landskrona Sweden Address Besam SW200i Type 100 240 V AC 10 15 50 60 Hz Mains power supply Max 300 W Power consumptio...

Page 8: ...the manual activation units 11 if any and walk towards the door Check that the door has opened appropriately while you pass the entrance exit Then proceed with the automatic activation units 12 in th...

Page 9: ...our months period The cleaning should be documented To avoid damages to the profiles the brushes weather stripping must be vacuum cleaned weekly Do not expose windows doors or profiles to alkalis Both...

Page 10: ...ean Union Product label Mandatory A Emergency break out Mandatory if approved for escape route B ASSA ABLOY Entrance Systems door sticker Mandatory if applicable to highlight the presence of the glass...

Page 11: ...ge 9 Finger protection 9 see page 9 Troubleshooting Remedies What s wrong The door does not open Change the setting of the program selector See page 6 The motor does not start Check that there are no...

Page 12: ...ive Environ ment Cycles hour in operation Part number Part 100 100 10 High traffic Medium traffic Low traffic 6 6 12 24 330000271 SI BK PUSH arm service kit 6 6 12 24 330000272 SI BK PULL arm service...

Page 13: ...C 60335 2 103 EN 60335 2 103 UL 325 EC type examination or certificate issued by a notified or competent body for full address please contact ASSA ABLOY Entrance Systems AB concerning the equipment UL...

Page 14: ...ASSA ABLOY Entrance Systems AB Lodjursgatan 10 SE 261 44 Landskrona Sweden Tel 46 10 47 47 000 Fax 46 418 284 12 www assaabloyentrance com info aaes assaabloy com...

Reviews: