Service/Maintenance
As mentioned earlier in this manual, service and adjustments performed by your ASSA ABLOY Entrance
Systems-authorized representative will ensure safe and proper operation of your automatic door
unit.
Remember to keep “Service Log Book” and “Site Acceptance Test and Risk Assessment” documents
(PRA-0007) available. These are used together.
The table below shows the recommended interval in months, when to replace parts during preventive
maintenance. Talk to your ASSA ABLOY Entrance Systems representative to learn more about our
service offering.
Abusive
Environ-
ment
Cycles/hour in operation
Part number
Part
>100
<100
<10
High
traffic
Medium
traffic
Low
traffic
6
6
12
24
330000271 SI/BK
PUSH arm service kit
6
6
12
24
330000272 SI/BK
PULL arm service kit
6
6
12
24
330000276
Stop arm kit
6
6
12
24
330000275
Micro switch kit
6
6
12
24
330000270 SI/BK
Adaptor kit
60
60
60
60
331007291
Transmission unit
60
60
60
60
331008346
Control unit CU-200 with EXU-
boards
24
24
24
24
33738753
Battery