9.4
Labels
Label kit P/N: 331007317
DO NOT
ENTER
AUTOMATIC
DOOR
75-20-101
AUTOMATIC
DOOR
75-20-100
Dual Side “AUTOMATIC DOOR / DO NOT EN-
TER” – In
Dual Side “AUTOMATIC DOOR / DO NOT EN-
TER” – Out
21-24-005
AUTOMATIC
DOOR
CAUTION
75-20-102
Dual side "Operator designed for disabled people"
Dual Side “AUTOMATIC DOOR / CAUTION”
PULL TO
ACTIVATE
PUSH TO
ACTIVATE
Pull side “PULL TO ACTIVATE”
Push side “PUSH TO ACTIVATE”
ACTIVATE
SWITCH TO
OPERATE
"Danger"
Dual Side “Activate Switch to Operate”
These minimal safety
checks in addition to
those in the Owner’s
Manual, should be made
each day and after any
loss of electrical power.
PLACE COMPLETED
ANNUAL COMPLIANCE
INSPECTION LABEL
HERE
#50-24-020
DO NOT USE DOOR if it
falls any of these safety
checks or if it
malfunctions in any way.
Call a qualified automatic
door service company to
have door repaired or
serviced.
See Owner’s Manual or
instructions for details on
each of these and other
safety items. If you need a
copy of the manual,
contact the manufacturer.
1.
Walk toward the door at a
normal pace. Door should
open when you are about 4
feet from the door.
2.
Stand motionless on
threshold for at least 4
seconds. Door should not
contact you.
3.
Walk into the swing area and
stop for 10 seconds. Door
should not contact you.
4.
Move clear of the area. Door
should remain open for at
least 1.5 seconds and
should close slowly and
smoothly. If two-way traffic,
move toward swing side of
door. Door should open well
before you reach the swing
path.
5. Inspect the floor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
traffic path clear.
6. Inspect door’s overall
condition. The appropriate
signage should be
present.
Guide rails and finger guards
should be in good condition.
7. Have door inspected by an
AAADM certified inspector at
least annually.
SAFETY INFORMATION
Automatic Swinging
Doors
SAFETY INFORMATION
Low Energy Swinging
Doors
These minimal safety
checks in addition to
those in the Owner’s
Manual, should be made
each day and after any
loss of electrical power.
PLACE COMPLETED
ANNUAL COMPLIANCE
INSPECTION LABEL
HERE
US24-0489-01
DO NOT USE DOOR if it
falls any of these safety
checks or if it malfun-
ctions in any way. Call a
gualified automatic door
service company to have
door repaired or serviced.
See Owner’s Manual or
instructions for details on
each of these and other
safety items. If you need a
copy of the manual,
contact the manufacturer.
1. Activate the door. Door
should be open at a slow
smooth pace (4 or more
seconds), and stop without
impact.
2. Door must remain fully open
for a minimum of 5 seconds
before beginning to close.
3. Door should close at a slow
smooth pace (4 or more
seconds), and stop without
impact.
4. Inspect the floor area. It
should be clean with no
loose parts that might cause
user to trip or fall. Keep
traffic path clear.
5. Inspect door’s overall
condition. The appropriate
signage should be in good
condition.
6. Have door inspected by an
AAADM certified inspector at
least annually.
#US24-0542-01
ANNUAL COMPLIANCE
INSPECTION
Inspected for and complies with
ANSI A156. _______________
DATE: _______________
by AAADM Certified
Inspector
Number:_______________
"Safety information"
"Certified Inspector"
25
Issue 2012-06-27
1007718-US-3.0
9 Options
Summary of Contents for Besam SW200i US
Page 26: ...Product label P N 1008999 1007718 US 3 0 Issue 2012 06 27 26 9 Options ...
Page 38: ...11 1 2 PULL PAS arm system 1007718 US 3 0 Issue 2012 06 27 38 11 Mechanical installation ...
Page 51: ...12 3 How to route the cables 51 Issue 2012 06 27 1007718 US 3 0 12 Electrical connection ...
Page 81: ......