Instructions for use and maintenance 

EN

IV.  DESCRIPTION AND PRINCIPLE OF WORK

The appliance consists of a body, flange, plastic 

control panel, safety return valve.

1. 

The body consists of a steel reservoir (water 

tank) and  plastic housing (outer shell) with 

thermal insulation placed in-between, and two 

pipes with thread G ½“, for cold water supply 

(marked with a blue ring) and hot water discharge 

(marked with a red ring). The inner reservoir 

is made of steel proved against corrosion by a 

special glass-ceramic coating.

2. 

The flange is outfitted with: electric heater 

and thermostat. The water heaters with glass-

ceramics coating are outfitted with a magnesium 

protector. 

The electric heater is used for heating the water in 

the tank and is managed by the thermostat, which 

automatically maintains the set temperature.
The thermostat has a built in overheating safety 

device, which switches of power to the heater 

when the water temperature reaches excessive 

values. 

3. 

The safety-return valve prevents the 

appliance's complete emptying in the event of 

cold water supply interruption. The valve protects 

the appliance from pressure increases higher 

than the allowed value during heating (! pressure 

will increase when temperature increases), by 

releasing the excess pressure through the drain 

outlet. Water dropping out through the drains 

during the warming process is a normal event 

that must be taken into consideration when the 

boiler is installed.

Attention

! The safety-return valve cannot protect 

the appliance in the event of water mains pressure 

in excess of the acceptable pressure stated for 

the appliance.

V.  MOUNTING AND SWITCHING ON

Attention

! Improper installation and connection of 

the appliance may make it hazardous for the health 

and life of consumers. It may cause grievous and 

permanent consequences, including but not limited to 

physical injuries and/or death. Improper installation and 

connection of the appliance may also lead to damage to the 

consumers’ property /damage and/ or destruction/, or to that 

of third persons, as a result of, but not limited to flooding, 

explosion  and/or  fire.  Installation,  connection  to  the  main 

water and power supply, and putting into operation must be 

carried out by certified electricians and technical personnel 

certified in installation of this category of appliances, who 

have obtained their license in the state where the installation 

and commissioning of the appliance are carried out, and in 

compliance with its local legislation

.

1. 

Mounting

 

We recommend installation of the device at 

close proximity to locations where hot water is 

used, in order to reduce heat losses during water 

transportation. The selected location must exclude 

the possibility of water spray originating from the 

showerhead or other water contacts.

The appliance is affixed to a wall by means of 

mounting brackets attached to the unit's body. Two 

hooks are used to fix the appliance (min. Ø 4 mm) 

firmly on the wall (included in the mounting set). 

The bearing plank construction for boilers installed 

above / under sinks

 is universal and allows the 

space between hooks to vary between 96 and 

114mm. (fig.2)

IMPORTANT: The type of boiler designed to 

be installed UNDER / ABOVE a sink is 

marked on the appliance. Boilers designed for 

installation 

above sinks

 are assembled in such a 

manner that the outlet/inlet pipes are pointed 

downwards (to the floor of the premise). Boilers 

designed for installation 

under sinks

 are 

assembled in such a manner that the outlet/inlet 

pipes are pointed upwards (to the ceiling of the 

premise). 

For clear understanding of wall installation 

schemes, please refer to fig.2 (A  above sink and B 

under sink).

Attention

! In order to prevent injury to user and/or 

third persons in the event of faults in the system for 

providing hot water, the appliance must be mounted 

in premises outfitted with floor hydro insulation (or) plumbing 

drainage. Don’t place objects, which are not waterproof 

under the appliance under any circumstances. In the event 

of mounting the appliance in premises not outfitted with floor 

hydro insulation, a protective tub with a plumbing drainage 

must be placed under the appliance.

Notice: the set does not include a protective 

tub and the user must select the same.

2. 

Water heater connection to the water 

supply system

Fig.4a

 - installation scheme above sink

Fig.4b

 - installation scheme under sink

Where: 1 – input pipe, 2 – safety valve (0.8 MPa), 

3 – reduction valve (if the water supply pressure 

exceeds 0,6 MPa), 4 – stop valve, 5 – bell-mouth 

discharge to the sewer, 6 – hose; 7 - Drain water 

tap.

Upon connecting the water heater to the water 

supply system, take care of the indicative color 

markings /rings/ of the pipes:  

BLUE

 -  for cold /in-flowing/ water,  

RED

 -  for hot /out-flowig/ water.

The mounting of the safety return-valve supplied 

with the water heater is obligatory. The safety 

return-valve must be installed on the cold water 

supply pipe, according to the arrow stamped on its 

body that indicates the supplied water direction. 

Exception: If the local regulations (norms) 

require the usage of another protection valve 

or mechanism (in accordance with EN 1487 or EN 

1489), then it must be bought additionally. For 

mechanisms operating in accordance with EN 

1487 the announced operational pressure must be 

no more than 0.7 MPa. For other protection valves, 

the pressure at which they are calibrated must be 

0.1 MPa lower than the one marked on the 

appliance’s sign. In these cases the safety valve 

which the appliance is supplied with should not be 

used

.

Summary of Contents for ATE15C

Page 1: ...nstructions for use and maintenance ES TERMO DE AGUA ELÉCTRICO 07 11 Instrucciones de uso y mantenimiento Read this manual carefully and keep it for future reference Lea atentamente este manual y guárdelo para futuras consultas ATE15C ...

Page 2: ...iance is recommended as well as usage of not more than 2 kW of heating power II TECHNICAL PARAMETERS 1 Nominal volume V liters see the appliance s rating plate 2 Nominal voltage see the appliance s rating plate 3 Nominal power consumption see the appliance s rating plate 4 Nominal pressure see the appliance s rating plate This is not the water mains pressure This is the pressure that is announced ...

Page 3: ...ndergo regular cleaning and inspections for normal functioning the valve must not be obstructed and for the regions with highly calcareous water it must be cleaned from the accumulated lime scale This service is not provided under warranty maintenance All alterations and modifications to the water heater s construction and electrical circuitry are forbidden If such alterations or modifications are...

Page 4: ...tion The selected location must exclude the possibility of water spray originating from the showerhead or other water contacts The appliance is affixed to a wall by means of mounting brackets attached to the unit s body Two hooks are used to fix the appliance min Ø 4 mm firmly on the wall included in the mounting set The bearing plank construction for boilers installed above under sinks is univers...

Page 5: ...erly The Manufacturer does not assume any liability for problems arising out of the appliance s improper use 3 Water heater s electrical connection fig 3 ATTENTION Before you switch the power supply make sure the appliance is full of water 3 1 Models fit with power supply cord combined with a plug shall be plugged in a socket The boiler can be disconnected from the power supply by unplugging ATTEN...

Page 6: ...nce of high temperature lime scale the so called lime scale layer is deposited upon the heating element s surface This worsens the heat exchange between the heating element and water The heating element s surface temperature increases along of boiling water The thermoregulator begins to switch on and off more frequently A deceptive activation of the thermal protection is possible Due to these fact...

Page 7: ...ciada para el aparato y se refiere a los requisitos de las normas de seguridad 5 Tipo de termo termo cerrado de acumulación con aislamiento térmico 6 Consumo diario de electricidad ver Anexo I 7 Perfil de carga nominal ver Anexo I 8 Cantidad de agua mezclada a 40 C V40 en litros ver Anexo I 9 Temperatura máxima del termostato verAnexo I 10 Ajustes de temperatura de serie ver Anexo I 11 Eficiencia ...

Page 8: ...n de la cal acumulada Este servicio no está incluido en los terminos de la garantia Queda terminantemente prohibido realizar modificaciones o cambios tanto en la estructura como en el circuito electrico del termo Si se detecta alguna modificacion durante la inspeccion del aparato la garantia quedara anulada inmediatamente Por modificaciones o cambios se entienden la eliminacion de piezas o compone...

Page 9: ... la reparación y el montaje del equipo que han adquirido sus competencias profesionales en el territorio del país donde se lleva a cabo el montaje y la puesta en marcha del equipo y en conformidad con su normativa 1 Instalación Se recomienda la instalación del termo eléctrico en las proximidades de los lugares donde se utiliza el agua caliente con el fin de reducir las pérdidas de calor durante el...

Page 10: ... termo 3 Desmontar el termo de su lugar de instalación girelo de forma tal de que los caños se orienten hacia abajo y vierta el agua en un recipiente que ha preparado a tal efecto Espere hasta que toda el agua se drene del termo Si la presión en la red de agua supera a las cantidades los valores indicados en el párrafo 1 mas es necesaria la instalación de una válvula de reducción de presión de lo ...

Page 11: ...ienda realizar una inspección periódica del ánodo por un técnico autorizado así como su sustitución en caso de necesidad Para realizar el recambio contacte a los servicios autorizados VIII MANTENIMIENTO PERIÓDICO En caso de función normal del calentador bajo la influencia de la alta temperatura de la superficie del calentador se difiere caliza o sea piedra de caldera Esto empeora el cambio de calo...

Page 12: ...ay differ Nota La ilustración es una imagen de referencia su aparato podría diferir Models A mm B mm D mm C mm GCU 10 372 384 270 100 GCU 15 372 384 337 100 GCA 10 372 384 270 100 ATE15C 372 384 337 100 C G1 2 G1 2 B A 20 D 20 D C G1 2 G1 2 B A 200 223 119 119 ...

Page 13: ...Note The illustration is a reference image your device may differ Nota La ilustración es una imagen de referencia su aparato podría diferir 2a І І P P 10 mm min 96 mm max 114 mm 1 3 2 4 8 mm ...

Page 14: ...2b Note The illustration is a reference image your device may differ Nota La ilustración es una imagen de referencia su aparato podría diferir І І P P 8 mm 10 mm min 96 mm max 114 mm 1 3 2 4 ...

Page 15: ...3 4 4ⓐ 4ⓑ 5 L A N B TR TS R IL 1 2 min max Note The illustration is a reference image your device may differ Nota La ilustración es una imagen de referencia su aparato podría diferir ...

Page 16: ...205912_001 ...

Reviews: