Instructions for use and maintenancе

       

3

EN

English

be taken to connect the safety lead.

 

If the probability exists for the premise’s temperature to fall below 0 

°C, the water heater must be drained (observe the procedure outlined 

in section V, subsection 2 ‘’Water heater’s piping connection”).

 

During use (water heating mode), the dripping of water from the 

safety return-valve’s drainage opening is normal. The same must 

be left open to the atmosphere. Measures should be taken to lead 

and collect the leakages in order to prevent damages, ensuring 

that this is in conformation with the requirements described in p. 2 

in paragraph V.

 

The valve and the elements linked to it must be protected from 

freezing.

 

During the heating the appliance could produce a hissing noise 

(the boiling water). This is common and does not indicate any 

damage. The noise gets higher with the time and the reason for 

this is the accumulation of limestone. To remove the noise the 

appliance must be cleaned from limestone. This type of cleaning is 

not covered by the warranty.

 

In order to secure the water heater’s safe operation, the safety 

return-valve must undergo regular cleaning and inspections for 

normal functioning /the valve must not be obstructed/, and for 

the regions with highly calcareous water it must be cleaned from 

the accumulated lime scale. This service is not provided under 

warranty maintenance.

 

All alterations and modifications to the water heater’s construction 

and electrical circuitry are forbidden. If such alterations or modifications 

are established during inspection, the appliance’s warranty shall be null 

and void. Alterations and modifications shall mean each instances of 

removal of elements incorporated by the manufacturer, building in of 

additional components into the water heater, replacement of elements 

by similar elements unapproved by the manufacturer.

 

If the power supply cord (of models that have one) is damaged, 

it must be replaced by a service representative or a person with 

similar qualification, to avoid any risk.

 

This appliance can be used by children aged from 8 years and 

above and persons with reduced physical, sensory or mental 

capabilities or lack of experience and knowledge if they have been 

given supervision or instruction concerning use of the appliance in 

a safe way and understand the hazards involved. 

 

Children shall not play with the appliance. 

 

Cleaning and user maintenance shall not be made by children 

without supervision.

Summary of Contents for ATE15C

Page 1: ...nstructions for use and maintenance ES TERMO DE AGUA ELÉCTRICO 07 11 Instrucciones de uso y mantenimiento Read this manual carefully and keep it for future reference Lea atentamente este manual y guárdelo para futuras consultas ATE15C ...

Page 2: ...iance is recommended as well as usage of not more than 2 kW of heating power II TECHNICAL PARAMETERS 1 Nominal volume V liters see the appliance s rating plate 2 Nominal voltage see the appliance s rating plate 3 Nominal power consumption see the appliance s rating plate 4 Nominal pressure see the appliance s rating plate This is not the water mains pressure This is the pressure that is announced ...

Page 3: ...ndergo regular cleaning and inspections for normal functioning the valve must not be obstructed and for the regions with highly calcareous water it must be cleaned from the accumulated lime scale This service is not provided under warranty maintenance All alterations and modifications to the water heater s construction and electrical circuitry are forbidden If such alterations or modifications are...

Page 4: ...tion The selected location must exclude the possibility of water spray originating from the showerhead or other water contacts The appliance is affixed to a wall by means of mounting brackets attached to the unit s body Two hooks are used to fix the appliance min Ø 4 mm firmly on the wall included in the mounting set The bearing plank construction for boilers installed above under sinks is univers...

Page 5: ...erly The Manufacturer does not assume any liability for problems arising out of the appliance s improper use 3 Water heater s electrical connection fig 3 ATTENTION Before you switch the power supply make sure the appliance is full of water 3 1 Models fit with power supply cord combined with a plug shall be plugged in a socket The boiler can be disconnected from the power supply by unplugging ATTEN...

Page 6: ...nce of high temperature lime scale the so called lime scale layer is deposited upon the heating element s surface This worsens the heat exchange between the heating element and water The heating element s surface temperature increases along of boiling water The thermoregulator begins to switch on and off more frequently A deceptive activation of the thermal protection is possible Due to these fact...

Page 7: ...ciada para el aparato y se refiere a los requisitos de las normas de seguridad 5 Tipo de termo termo cerrado de acumulación con aislamiento térmico 6 Consumo diario de electricidad ver Anexo I 7 Perfil de carga nominal ver Anexo I 8 Cantidad de agua mezclada a 40 C V40 en litros ver Anexo I 9 Temperatura máxima del termostato verAnexo I 10 Ajustes de temperatura de serie ver Anexo I 11 Eficiencia ...

Page 8: ...n de la cal acumulada Este servicio no está incluido en los terminos de la garantia Queda terminantemente prohibido realizar modificaciones o cambios tanto en la estructura como en el circuito electrico del termo Si se detecta alguna modificacion durante la inspeccion del aparato la garantia quedara anulada inmediatamente Por modificaciones o cambios se entienden la eliminacion de piezas o compone...

Page 9: ... la reparación y el montaje del equipo que han adquirido sus competencias profesionales en el territorio del país donde se lleva a cabo el montaje y la puesta en marcha del equipo y en conformidad con su normativa 1 Instalación Se recomienda la instalación del termo eléctrico en las proximidades de los lugares donde se utiliza el agua caliente con el fin de reducir las pérdidas de calor durante el...

Page 10: ... termo 3 Desmontar el termo de su lugar de instalación girelo de forma tal de que los caños se orienten hacia abajo y vierta el agua en un recipiente que ha preparado a tal efecto Espere hasta que toda el agua se drene del termo Si la presión en la red de agua supera a las cantidades los valores indicados en el párrafo 1 mas es necesaria la instalación de una válvula de reducción de presión de lo ...

Page 11: ...ienda realizar una inspección periódica del ánodo por un técnico autorizado así como su sustitución en caso de necesidad Para realizar el recambio contacte a los servicios autorizados VIII MANTENIMIENTO PERIÓDICO En caso de función normal del calentador bajo la influencia de la alta temperatura de la superficie del calentador se difiere caliza o sea piedra de caldera Esto empeora el cambio de calo...

Page 12: ...ay differ Nota La ilustración es una imagen de referencia su aparato podría diferir Models A mm B mm D mm C mm GCU 10 372 384 270 100 GCU 15 372 384 337 100 GCA 10 372 384 270 100 ATE15C 372 384 337 100 C G1 2 G1 2 B A 20 D 20 D C G1 2 G1 2 B A 200 223 119 119 ...

Page 13: ...Note The illustration is a reference image your device may differ Nota La ilustración es una imagen de referencia su aparato podría diferir 2a І І P P 10 mm min 96 mm max 114 mm 1 3 2 4 8 mm ...

Page 14: ...2b Note The illustration is a reference image your device may differ Nota La ilustración es una imagen de referencia su aparato podría diferir І І P P 8 mm 10 mm min 96 mm max 114 mm 1 3 2 4 ...

Page 15: ...3 4 4ⓐ 4ⓑ 5 L A N B TR TS R IL 1 2 min max Note The illustration is a reference image your device may differ Nota La ilustración es una imagen de referencia su aparato podría diferir ...

Page 16: ...205912_001 ...

Reviews: