VIPEDIA-12 – Installation Guide
U-0641-0344.doc – Issue: 06 complete, approved
Page 8 of 44
2 Installation
2.1
Equipment and Tool Requirements
•
The VIPEDIA-12 unit
•
Cabling as specified in “External Cabling Requirements” (page 9) to suit your system design
•
A small flat-bladed screwdriver
•
Pozidriv screwdrivers (No. 1 and No. 3)
•
A pair of wire cutters/strippers
•
A 19-inch standard rack fitted with supporting rails and wired with power supply, signal, and control
wiring, as required by your specific system design
DIN rail mounting Break-Out Adaptors (BOA) are available for easier rack wiring.
BOA01 (ASL P/N A0641006)
Screw-in terminals: external wiring
RJ45: VIPEDIA-12
EOL and ANS resistors: factory fit option
BOA02 (ASL P/N A0664244)
Screw-in terminals: external wiring
RJ45: VIPEDIA-12
!
!
If the VIPEDIA-12 is intended to be table or shelf mounted, i.e. not in a 19-inch standard rack, then
the unit should always be fitted into a 19-inch desk case or flight case. This is to prevent ingress of
dust or debris that may otherwise occur over a period of time.