VIPEDIA-12 – Installation Guide
U-0641-0344.doc – Issue: 06 complete, approved
Page 27 of 44
3.2.1.4
BOA01 - Contact Inputs (1 to 12) Connections
Field Connection
Screw-in Terminal
①
Connection to VIPEDIA-12
(via CAT5 patch lead)
Description Signal
Pin
+V supply input (18 – 40 V) / 500 mA
24 V
1
+V supply input (18 – 40 V) / 500 mA
24 V
2
From
external
power supply
0 V supply
0 V
3
Not applicable
(Connected to screw-in terminal
③
via the PCB.)
VIPEDIA-12’s
RJ45
Screw-in Terminal
②
BOA01’s
RJ45
④
⑨
Description Signal
Pin
Pin
Pin
Opto-isolated contact 1 [5, 9] (+ve) or
Analogue contact 1 [5, 9]
CI1+ [5, 9]
1
1
1
Opto-isolated contact 1 [5, 9] (-ve)
CI1- [5, 9]
2
2
2
Opto-isolated contact 2 [6, 10] (+ve) or
Analogue contact 2 [6, 10]
CI2+ [6, 10]
3
3
3
Opto-isolated contact 2 [6, 10] (-ve)
CI2- [6, 10]
4 6
6
Opto-isolated contact 3 [7, 11] (+ve) or
Analogue contact 3 [7, 11]
CI3+ [7, 11]
5 4
4
Opto-isolated contact 3 [7, 11] (-ve)
CI3- [7, 11]
6 5
5
Opto-isolated contact 4 [8, 12] (+ve) or
Analogue contact 4 [8, 12]
CI4+ [8, 12]
7
7
7
Opto-isolated contact 4 [8, 12] (-ve)
CI4- [8, 12]
8
8
8
Screw-in Terminal
③
Description Signal
Pin
Cable screen
SCREEN
1
DC supply output (18 – 40 V)
2
Cable screen
SCREEN
3
DC supply output (0 V)
0V
4
Cable screen
SCREEN
5
DC supply output (18 – 40 V)
6
Cable screen
SCREEN
7
To/From
external
device
DC supply output (0 V)
0V
8
Not applicable
1) An external DC power supply (18 – 40 V) must be connected to screw-in terminal
①
if the external device is to
be powered from the screw-in terminal block
③
.
2) Contact: Numbers without brackets refer to CONTACTS IN 1-4 connector. Numbers within brackets refer to
CONTACTS IN 5-8 and 9-12 connector.
3) Contact is configurable as digital or analogue.
4) Internal
4k7
Ω
pull-up to +5 V is configurable per port.
5) EOL resistors for digital contacts can be fitted to the BOA01 in manufacture as required.