Service menu cont.
Turn/
Push
Display
Comments/instructions
Test
No component tested
D
IA
G
N
O
ST
IC
S
Test motor
The motor runs at normal speed
Test heater 1
The motor runs at normal speed. Heating element 1 is switched on and off by the CU
depending on the values registered by thermistors 1 and 2. Max. temp. 70°C. (Only if
setting for heat pump is
Heat Pump Off
)
Test heater 2
The motor runs at normal speed. Heating element 2 is switched on and off by the CU
depending on the values registered by thermistors 1 and 2. Max. temp. 70°C. (Only for
condenser and vented machines and where setting for steam is
Steam Off
)
Testing compressor
Temperature sequence on (only machines with heat pump)
Testing switching valve
Switching valve on (only machines with heat pump)
Testing fan/HWC
Fan/Valve on (Fan only for machines with heat pump and Valve only for HWC)
Test drain
The condensed water pump starts (only condenser machines and heat pump)
Test buzzer
Buzzer on continuously
Auto extratorrt
Auto skåptorrt
Tidsprogram
Auto normaltorrt
Auto stryktorrt
Luftningsprogram
T 7 5 3 C
B U T T E R F L Y D R Y I N G
Dry level 0
Drying time extended by 0, default setting
D
R
Y
L
E
V
EL
Dry level +5
Drying time extended by 5 min
Dry level +10
Drying time extended by 10 min
Dry level +15
Drying time extended by 15 min
Dry level +20
Drying time extended by 20 min
Auto extratorrt
Auto skåptorrt
Tidsprogram
Auto normaltorrt
Auto stryktorrt
Luftningsprogram
T 7 5 3 C
B U T T E R F L Y D R Y I N G
Auto extra dry
Off
Setting to make
Programme 1 - Auto extra dry
selectable/non-selectable in the
programme menu.
B
LO
C
K
P
R
O
G
R
A
M
S
On
Auto dry
Off
Setting to make
Programme 2 - Auto dry
selectable/non-selectable in the programme
menu.
On
Auto normal dry
Off
Setting to make
Programme 3 - Auto normal dry
selectable/non-selectable in the
programme menu.
On
Auto extra dry
Off
Setting to make
Programme 4 - Auto extra dry, low temperature
selectable/non-
selectable in the programme menu.
On
Auto dry
Off
Setting to make
Programme 5 - Auto dry, low temperature
selectable/non-selectable
in the programme menu.
On
Auto normal dry
Off
Setting to make
Programme 6 - Auto normal dry, low temperature
selectable/non-
selectable in the programme menu.
On
Auto iron dry
Off
Setting to make
Programme 7 - Auto iron dry, low temperature
selectable/non-
selectable in the programme menu.
On
Auto extratorrt
Auto skåptorrt
Tidsprogram
Auto normaltorrt
Auto stryktorrt
Luftningsprogram
T 7 5 3 C
B U T T E R F L Y D R Y I N G
Coin Off
Setting for coin operations Off, default setting
C
O
IN
Coin On
Setting for coin operations On
Auto extratorrt
Auto skåptorrt
Tidsprogram
Auto normaltorrt
Auto stryktorrt
Luftningsprogram
T 7 5 3 C
B U T T E R F L Y D R Y I N G
S3
J1
DISPLAY
S2
S1
Service Manual TD70.C
26