This document must not be copied without
our written pemission, and the contents
thereof must not be imparted to a third party
nor be used for any unauthorized purpose.
Contravention will be prosecuted.
Asko Appliances AB
CIRCUIT DIAGRAM TD70.C 440 V
80 902 59 - 00
WIRES IN SOME MACHINES
INTERNAL CONNECTION
NTC 1
E
L 1
05
0 W
F
AP
SERVICE MENU
TURN OFF POWER (S1)
WAIT FOR AT LEAST 5 SEC
HOLD S2
TURN ON POWER (S1)
PRESS S2 5 TIMES TO ENTER SERVICE MENU
PRESS STOP (S3) TO CHANGE MENU STEP
ROTATE DIAL TO CHANGE IN STEP
PRESSING START (S2) STORES AND EXITS SERVICE MENU
E
L 1
95
0 W
T2
DB
FB
L1
L2
MO
T1
NTC 2 *A
WIRES IN ALL MACHINES
*A
*A CONDENSE MACHINES
CABLE POSITIONS
1: THERMISTOR
4: MOTOR, DRAIN PUMP, FLOAT SWITCH
5: DOOR SWITCH
6: COMMUNICATIONS INTERFACE
7: COINMETER
8: POWER
9: HEATING ELEMENT
RESISTANCES AT ROOM TEMPERATURE (CA. 20°C/68°F)
VALUES WITH +/-10% ARE REGARDED AS NORMAL
COMPONENT
F: RADIO INTERFERENCE SUPPRESSION FILTER 680K Ohm
NTC 1: THERMISTOR 1 4 - 6 K Ohm
NTC 2: THERMISTOR 2: 4 - 6 K Ohm
AP: DRAIN PUMP: 111 Ohm
EL: HEATING ELEMENT 1050W 167,6 Ohm
EL: HEATING ELEMENT 1950W 90,2 Ohm
MO: MOTOR
T1: THERMOSTAT, OVERHEATING (HEATER)
T2: THERMOSTAT, OVERHEATING (HEATER)
FB: FLOAT SWITCH
DB: DOOR SWITCH
T: TRANSFORMER 440V/230V
S2 S3
S1
*A
F1
F2
USER SETTINGS MENU
TURN OFF POWER (S1)
WAIT FOR AT LEAST 5 SEC
HOLD S3
TURN ON POWER (S1)
PRESS S3 5 TIMES TO ENTER MENU
2011-07-07
R
B
R
A
R
44
R
43
R
B
R
A
R
44
R
43
R
33
R
34
T
Blue
Orange
MO
Service Manual TD70.C
17