9
4.Component description
4.1 Components and measurement values
The specified resistance values apply at room temperature (about 0°C/8°F)
Values within ±10% are considered normal.
COMPONeNT DeSCRIPTION
Article no.
Position Component
807779
EMC filter
80 kohm
807780,81
EMC filter
1 Mohm
807950
Heating element 100 W
0 V
ohm
8079505
Heating element 100 W
10 V
1 ohm
807809
Thermistor
0 kohm
807801,0
Combi disp. 0 V
1. kohm
80780,0
Combi disp. 10 V
0. kohm
8078080
8078080
Circ. pump 0/0 V 50
Hz
Primary winding 115 ohm
Circ..pump 0-0 V 50
Hz
Auxiliary winding 0 ohm
807808
807808
Circ..pump 10 V 0 Hz Primary winding 1, ohm
Circ..pump 10 V 0 Hz Auxiliary winding 7 ohm
8078081
8078081
Circ. pump 0-0 V
0 Hz
Primary winding 78 ohm
Circ. pump 0-0 V
0 Hz
Auxiliary winding 15 ohm
8078087
Drainage pump 00/0 V
50 Hz, 1 l/min
18 ohm
8078088
Drainage pump 00/0 V
0 Hz, 1 l/min
85 ohm
8078089
Drainage pump 10V 0
Hz, 1 l/min
ohm
807808
-
Spray arm diverter 0 V
50/0 Hz
8.5 kohm
8078085
-
Spray arm diverter 10 V
0 Hz
. kohm
807950
Inlet valve single 00/0
V, l/min
.9 kohm
807950
Inlet valve single 10 V,
l/min
0.95 kohm
8079500
Inlet valve fuse 0/0
V, l/min
kohm
8079501
Inlet valve fuse 10 V,
l/min
0.5 kohm
Summary of Contents for DW70.1
Page 1: ...SERVICE MANUAL DISHWASHERS DW70 1 DW70 3 DW70 4 DW70 5...
Page 2: ......
Page 33: ...33 Article no 80 836 38 rev 01...