5.5 Program flow description
Presented below is the Quick program. If the component test in the service menu is not sufficient to
identify a fault you can run this program and compare the results with the flow description below. If they
are in agreement this indicates a correctly functioning control unit.
Component
Time
Comments
Main wash
Drainage pump
sec.
5 sec. if the previous program was cancelled
with the Start/Stop button
Inlet valve
0/5 sec.
With/without diverter
Circ. pump
0 sec.
Circ. pump & Combi dispenser sec.
Circ. pump
10 sec.
Circ. pump & Element T-0º/5º
Eco/Normal temp
Circ. pump
180 sec.
Circ. pump & Element T-0º/0º
Eco/Normal temp
SCS
sec.
Super Clean System
Drainage pump
5 sec.
1st rinse
Inlet valve
7 sec.
Circ. pump
sec.
Pause
5 sec.
Circ. pump
sec.
Drainage pump
sec.
Inlet valve
0/5 sec.
With/without diverter
Circ. pump
90 sec.
SCS
sec.
Super Clean System
Drainage pump
5 sec.
Final rinse
Inlet valve
0/5 sec.
With/without diverter
Circ. pump & Element T-0/0º
Eco/Normal drying
Circ. pump & Combi dispenser sec.
None Eco drying
Circ. pump
sec.
No Eco drying
Circ. pump & Combi dispenser 0 sec.
No Eco drying
Circ. pump
90/0 sec.
Eco/Normal drying
Pause
0 sec.
Drainage pump
5 sec.
Fan
00 sec.
Normal drying