background image

Exploded View of Wash System

020820 (MECH)

The drain hose must have a loop at a

minimum height of 32 inches

 in order to

insure proper drainage.

The main pump can easily be removed by
disconnecting the drain pump connector

hose and the wiring harness connections

made at the circulation motor and rotating
the four sump retainers toward the middle of

the sump.

Pump Assembly

The pump assembly is driven by a
synchronous motor. Rotation is in the

counterclockwise direction at 3600 RPM.

The motor drives a pump which supplies
100 percent filtered water at a rate to

approximately 12 GPM.

Draining is accomplished by using a small
separate synchronous drain pump mounted

to the side of the sump. The drain pump is

connected to the main pump by a small
rubber hose. The drain check valve is

located at the discharge end of the drain

pump. The drain hose is attached by a worm
gear clamp to the discharge end of the drain

pump.

900 Watt Heater

Refer to the cycle chart on the reverse side

to determine when the heater is on during
the wash cycle.

Voltage checks of the heater should be
made with the timer set in the main wash.

Tub and Door Seal

The door seal is pressed into the tub

channel for an interference fit. Center the
gasket (marked on back) at the tub top

center and press in place without stretching

or bunching. The gasket takes a short turn
at the bottom of the tub channel before

ending at the channel end wall.

Mounting
Rib

Tub
Interior

Gasket Cross Section

Short Turn

Product Specifications

Water Supply

Minimum incoming water temperature ............

................................................... 120°F (49°C)

Pressure (PSI) min./max. ..................... 20/120
Connection (NPT) .......................................

3

/

8

Consumption (Normal Cycle) .........................

......................................... 7.2 gal., 27.3 liters

Electrical

Rating ..................................... 120 Volts, 60Hz
Separate Circuit ... 15 amp min.- 20 amp max.
Motor (Amps) ............................................. 1.1

Heater Wattage ......................................... 900

Total Amps (load rated) ............................ 10.0

Trouble Shooting Tips

Electric Shock Hazard

Check the list below each symptom.  Repair or replace defective components as encountered.

Symptom. . .Dishwasher will not operate
when turned on (wait at least 90 seconds).

1. Fuse (blown or tripped).
2. 120 VAC supply wiring connection faulty.
3. Timer (contacts open or defective)
4. Motor (inoperative).
5. Door switch (open contacts).
6. Door latch not making contact with door

switch.

7. Selector switch (open contacts).

Symptom. . .Motor hums but will not start or
run.

1. Motor (bad bearings or locked rotor).
2. Motor stuck due to prolonged

non-use.

Symptom. . .Motor trips out on internal
thermal overload protector.

1. Improper voltage.
2. Motor shaft binding.
3. Motor windings shorted.
4. Glass or foreign items in pump.

Symptom. . .Dishwasher runs but will not
heat.

1. Heater element (open).
2. Timer defective.
3. Wiring or terminal defective.

Symptom. . .Dishwasher will not pump out.

1. Drain restricted.
2. Timer contact defective.
3. Defective drain pump.
4. Air lock in drain hose.
5. Blocked impeller.
6. Open windings.

Symptom. . .Dishwasher will not fill with
water.

1. Water supply turned off.

2. Defective water inlet fill valve.

3. Check fill valve screen for obstructions.

4. Defective float switch.

5. Timer contact defective.

6. Wiring defective.

7. Float stuck in “UP” position.

Symptom. . .Timer does not advance.

1. Timer motor (stalled or open.)

2. Check timer for power to timer motor.

3. Timer shaft binding to or knob interference

with escutcheon.

Symptom. . .Dishwasher water siphons out.

1. Drain hose (high) loop too low--must be a

minimum height of 32 inches.

2. Drain line connected to a floor drain not

vented. (Install air gap at counter top.)

Disconnect electrical power at the fuse box or circuit breaker box before

adjusting or replacing components. Failure to follow this warning could

result in death or serious injury

.

Drain Hose
(32" minimum
height)

Heating Element

Filter

Soil Director

Volute Cover

Drain Motor

Connector Hose and Clamps

Sump

Incoming Water Supply

Water Valve

Water Inlet Tube
Circulation

Nut

Lower Spray Arm/Tower Assembly

Motor
Bracket

Motor Assembly

Sump Retainers (4)

Reviews: