4

Illustration

Solution

Cause 

Investigation

Indication

Refill 

button

Transformer: Check operation 

with functioning transformer. 

Where necessary replace with 

appropriate transformer. For part 

numbers see spare parts list. 

Refill button on pump 

does not activate the 

pump.

Sensor is not 

blinking  when 

hand is placed 

in front

 Pump is not

 making sound

 when the sensor

is activated

 Foam not

dispensing

Min 300 mm.

Bottom of the washbasin

Eliminate any cause of reflection 

and use appropriate remote 

control to shorten detection 

range.

Remote Control ref. number: 

07100005

Reflection issue from 

basin or other object

Replace

sensor

If the above two solutions have 

not resolved this issue replace 

with appropriate sensor. For part 

numbers see spare parts list. 

Sensor part number: 08002337

Damaged sensor 

1.  Increase the air to soap ratio.

Liquid rather than foam 

is being dispensed out 

of the nozzle

Foam not dispensing  

 

  

  

2. Verify that the filter is clean.

3.  Replace compressor (supplied 

with pump). For part numbers see 

spare parts list.

Use remote to decrease soap 

volume by pressing the "- Soap" 

key.

Foam dosage is too large

Foam is dispensing    

  

  

  

Use remote to increase soap 

volume by pressing the "+ Soap" 

key.

Foam dosage is too small

Use remote to decrease the 

amount of air in the foam by 

pressing the "- Air" Key.

Foam is too dense

Use remote to increase the 

amount of air in the foam by 

pressing the " + Air" key.

Foam is too liquefied