4
Illustration
Solution
Cause
Investigation
Indication
Refill
button
Transformer: Check operation
with functioning transformer.
Where necessary replace with
appropriate transformer. For part
numbers see spare parts list.
Refill button on pump
does not activate the
pump.
Sensor is not
blinking when
hand is placed
in front
Pump is not
making sound
when the sensor
is activated
Foam not
dispensing
Min 300 mm.
Bottom of the washbasin
Eliminate any cause of reflection
and use appropriate remote
control to shorten detection
range.
Remote Control ref. number:
07100005
Reflection issue from
basin or other object
Replace
sensor
If the above two solutions have
not resolved this issue replace
with appropriate sensor. For part
numbers see spare parts list.
Sensor part number: 08002337
Damaged sensor
1. Increase the air to soap ratio.
Liquid rather than foam
is being dispensed out
of the nozzle
Foam not dispensing
2. Verify that the filter is clean.
3. Replace compressor (supplied
with pump). For part numbers see
spare parts list.
Use remote to decrease soap
volume by pressing the "- Soap"
key.
Foam dosage is too large
Foam is dispensing
Use remote to increase soap
volume by pressing the "+ Soap"
key.
Foam dosage is too small
Use remote to decrease the
amount of air in the foam by
pressing the "- Air" Key.
Foam is too dense
Use remote to increase the
amount of air in the foam by
pressing the " + Air" key.
Foam is too liquefied