20
Z-Sensor and Z-Eurocard Operation Manual
Power Requirements
The Z-Sensor requires 10-28 Vdc and consumes 7.5 watts.
Environmental Specifications
The operating temperature range of the Z-Sensor is -30
°
C to +55
°
C; storage
temperature range is -40
°
C to +85
°
C.
The Z-Sensor will work at 100% humidity and is rated to MIL-STD-810E for wind
driven rain and dust.
RF Connector
The RF connector is a standard 50-ohm female TNC wired for connection via coaxial
cabling to a GPS antenna with integral LNA. The TNC connector shell is connected
to the Z-Sensor common ground. The TNC center pin pr5 Vdc to power the
LNA (maximum 150 mA draw) and accepts 1227 and 1575 MHz RF input from the
antenna; the RF and DC signals share the same path.
7
GND
20
CTSB-clear to send, port B
8
RTSB-ready to send, port B
21
RXDA-receive data, port A
9
TXDA-transmit data, port A
22
No connection
10
GND
23
CTSA-clear to send
11
RTSA-ready to send, port A
24
EXT PWR 1
12
GND
25
EXT PWR 2
13
GND
Table 2.4: Z-Sensor DB25 Connector Pinout (continued)
Pin
Code
Pin
Code
Summary of Contents for Z-eurocard
Page 4: ...iv Z Sensor and Z Eurocard Operation Manual...
Page 8: ...viii Z Sensor and Z Eurocard Operation Manual...
Page 10: ...x Z Sensor and Z Eurocard Operation Manual...
Page 18: ...8 Z Sensor and Z Eurocard Operation Manual...
Page 34: ...24 Z Sensor and Z Eurocard Operation Manual Figure 2 11 Z Sensor Development Kit B...
Page 35: ...Equipment 25 Equipment Figure 2 12 Z Eurocard Development Kit A...
Page 36: ...26 Z Sensor and Z Eurocard Operation Manual Figure 2 13 Z Eurocard Development Kit B...