14
© 2021 United States Stove Company
WARNING: RISK OF FIRE.
KEEP THE FEED DOOR TIGHTLY CLOSED AT
ALL TIMES EXCEPT WHEN TENDING THE FIRE.
DO NOT OPERATE THE UNIT WITH BROKEN
GLASS THIS WILL RESULT IN AN OVERFIRE
SITUATION.
For a cold start-up, place 3 to 4 pieces of newspaper
into the firebox. On top of the newspaper, lay 2
lbs of kindling in random placement to ensure
airflow through the kindling. On top of the kindling,
place approximately 3 to 4 lbs of small pieces of
cordwood. NOTE: Use smaller pieces of wood during
start-up and a high burn rate to increase the stove
temperature.
3-4 lb
Rotate the air control fully down. Light the
newspaper and close the door. Once the kindling
has burned down to a starter coal bed, load the unit
with approximately 12 to 13 lbs of fuel for the first
high burn load.
12 to 13 lbs
HIGH
After the first high burn load and the stove is well
warmed up, adjust the unit as needed for a medium
or low burn setting.
For a medium burn, once the high burn fuel load is
burned down to an established coal bed, load the
unit with 14 to 15 lbs of cordwood and close the door
immediately. Leave the air control fully open (in the
“HI” position) for 15 minutes. After 15 minutes rotate
the air control to the medium position (midway
between the “Low” and “Hi” position).
For a low burn setting once the high burn
(or medium) fuel load is burned down to an
established coal bed, load the unit with 14 to 15 lbs
of cordwood and close the door immediately. Leave
the air control fully open (in the “HI” position) for
15 minutes. After 15 minutes begin to rotate the air
control to the “Low” postion (air control rotated fully
up). NOTE: Do not close the air too quickly. Closing
the air too quickly will cause the unit to smoke.
MED
OPERATION INSTRUCTIONS