Installation
FLOOR PROTECTION
This heater must have a non-combustible
fl
oor protector (ember protection) installed beneath it if the
fl
oor is of combustible
material. If a
fl
oor pad is used, it should be UL listed or equal. The
fl
oor pad or non-combustible surface should be large
enough to cover at least the area under the product and 6 in. (152 mm) beyond the front and beyond each side of the fuel
loading and ash removal openings. Your heater will need a minimum 31” x 38”
fl
oor protector. Floor protection must extend
under and 2 in. (50.8mm) to each side of the chimney tee for an interior vertical installation (see FIGURE 2).
Canadian Installations require a minimum of 450 mm [17.7”] beyond the front of the unit and 200mm [7.8”] beyond each
side of the unit. A Floor Protector of ¼ inch thick is recommended for this installation.
THROUGH THE WALL INSTALLATION
INTERIOR VERTICAL INSTALLATION
7