Durability of the electrolytic cell
Lifetime of the electrolytic cell is 8000 running hours. The electrodes in the
electrolytic cell are made of titanium with a ruthenium and iridium layer. During
electrolysis this layer gets consumed. Durability of the electrodes is reduced by
the following parameters:
• Low salt content
• Water temperature below 10 ° C
• Low water fl ow
• Too hard water
• pH below 7.5
• Addition of metals containing preparations
Electrolysis cell cleaning
Electrolysis cell cleaning
In operation, the electrolysis cell is gradually clogged by sediments from the
hard water, that must be eliminated repeatedly. The clogging of the electrolysis
cell decreases the electrolysis cell capacity. In this case, the electrolysis cell
has to be taken out and submerged in the cleaning bath for about 10 minutes.
The coating should disappear and the electrolysis cell can be used again.
Electrode TE – 25