EN
24
Level sensor - Level Monitoring and Automatic Refi lling
Level measurement is performed by the
pressure-type level sensor
. This
allows the very easy installation of the sensor by its inserting into the storage
water reservoir or skimmer. Level is monitored at four heights that are easily
entered in centimetres of water height.
Setting:
High level ALARM - too much water in overfl ow tank
After this level is reached, following actions may start:
1.
If the automatic fi lter washing is enabled, one fi lter washing cycle starts and
drains the waste water.
2.
If the automatic fi lter washing is not enabled, the relay 19 switches on (fi lter
washing) for the period of time until level is OK. The second circulating
pump or automatic drain valve can be connected to this relay.
Filling OFF - required level
Refi lling stops
Filling ON - level at which refi lling starts
Refi lling starts after if the water level stay permanently at least for 10 seconds
below this value (in order to prevent oscillating)
Low level ALARM
Circulation (fi ltering) pump shuts off
Flowmeter
The fl owmeter detects fl ow of measured water. Dosing of chemicals will take
action only if fl ow of measured water to probes is detected.
Wash the check fl owmeter strainer on a regular basis.
Warning:
Only switch off the fl owmeter in case of a failure.
Delay
Delay time after dose
is time for which ASIN AQUA Salt does not dose
and wait for the dose response at the measuring water. At pools is average
response time 4 to 10 min, at SPA 1 to 10 min.
Delay time after start
(upon timer switching on) is time after start for which
Delay time after start
Delay time after start
ASIN AQUA Salt does not take any action and it waits for stabilization of a signal
from probes.
Concentration pH –
If you use the original ASEKO Pool & SPA chemicals keep the pre-adjusted
values. In case of use other non-original chemicals adjust concentration
according to data on the label of a chemical used.
Recommendation:
Use the original ASEKO Pool & SPA chemicals
Warning:
Higher concentrations of chemicals can result in shorter lifetime of
ASIN AQUA Salt components and may cause injury and health damage.
Hoch – Alarm
Niedrig – Alarm
Nachfüllen –
ON
Nachfüllen –
OFF
Aktuell
Niveau
Hoch – Alarm
Niedrig – Alarm
Nachfüllen –
ON
Nachfüllen –
OFF
Aktuell
Niveau
Niveau 0 cm
Actual
Level
Low level – Alarm
Level 0 cm
High level – Alarm
Filling –
ON
Filling –
OFF
Summary of Contents for ASIN AQUA Salt
Page 46: ...EN 46 ...
Page 47: ...EN 47 ...
Page 48: ...www asekopool com ASIN AQUA Salt VS USER MANUAL EN ...