7.4 - FUNCTIONAL FEATURES

Temperature Control: ON/OFF mode
Defrost control: interval cycles by stopping compressor

 

Measurement range: NTC: -50...109 °C / -58...228 °F; PTC:

 

-50...150 °C / -58 ... 302 °F
Display resolution: 1 ° or 0

.

1

 

° (range -99.9 ...99.9 °)

Overall accuracy: +/- (0

.

5 % fs + 1 digit)

Sampling rate: 130 ms.
Display: 3 Digit  Red (or Blue as option) h 15

.

5 mm

Software class and structure : Class A
Compliance: Directive  2004/108/CE (EN55022: class B;
EN61000-4-2: 8KV air, 4KV cont.; EN61000-4-3: 10V/m;
EN61000-4-4: 2KV

 

supply and relay outputs, 1KV inputs;

EN61000-4-5: supply 2KV

 

com. mode, 1 KV\ diff. mode;

EN61000-4-6: 3V);
Directive 2006/95/CE (EN 60730-1, EN 60730-2-9).
Regulation 37/2005/CE (EN13485 air, S, A, 2,

   

-50°C +90°C

with

 

probe NTC 103AT11).

7.5 - INSTRUMENT ORDERING CODE

Z31- 

(instrument with mechanical keyboard

 

)

Z31S 

(instrument with Sensitive Touch keyboard

 

)

a b c d e f g h ii jj

a : POWER SUPPLY
H

 =  Supply 100..240 VAC

G

 = Supply 12..24 VAC/VDC

F

 = Supply 12 VAC/VDC

b : OUT
R

 = Out Relay SPST-NO 16A

S

 = Out Relay SPDT 16A

c : BUZZER
-

= (No)

B

 = Buzzer

d : TERMINAL BLOCK
-

= (Standard)

E

 = Extractable screw terminal block complete

N

 = Extractable terminal block  without removable connectors

e : DISPLAY
-

= Red

= Blue

f, g, h : INTERNAL CODES

ii, jj : SPECIAL CODES

ASCON TECNOLOGIC - Z31- 

 

-OPERATING INSTRUCTIONS- Vr. 02 - 03/12 -  ISTR-MZ31-ENG02 -  PAG. 8

Advanced Thermoelectric       toll-free 1-866-665-5434      (603) 888-2467      [email protected]

ADVANCED THERMOELECTRIC

PO Box 1003, White River, VT 05055 USA

Toll-free: 1-866-665-5434

(603) 888-2467

 

[email protected]

Click here for: Comprehensive wiring and 

programming Instructions for use with 

ElectraCOOL

TM

 assemblies.

Summary of Contents for Z31

Page 1: ...TALLATION AND USE 3 KEYBOARD LOCK FUNCTION 2 6 RESET PARAMETERS TO DEFAULT VALUE LEVEL 2 5 CUSTOMIZED MODE PARAMETER PROGRAMMING PARAMETERS PROGRAMMING LEVEL 2 4 PARAMETER PROTECTION USING THE PASSWOR...

Page 2: ...identifies the first parameter Using the UP and DOWN keys the desired parameter can be selected and pressing the P key the display will alternately show the parameter code and its setting that can be...

Page 3: ...nting Make a hole 71 x 29 mm and insert the instrument fixing it with the provided special brackets We recommend that the gasket is mounted in order to obtain the front protection degree as declared A...

Page 4: ...r HC H SP off O N r HC H tim e r d SP Temp r d tim e r HC C O N O N ON ON O N off off off Temp Out Out In the event of probe error it is possible to set the instrument so that that the output continue...

Page 5: ...arm thresholds set in parameters A HA maximum alarm and A LA minimum alarm and the relative differential A Ad Through the parameter A Ay it is possible to set the alarm thresholds A HA and A LA which...

Page 6: ...nt Probes Type i SE 4 i parameters relative to inputs 0 0 LS HS Set Point SP 3 99 9 LS 999 Maximum Set Point S HS 2 50 0 99 9 HS Minimum Set Point S LS 1 S parameters relative to Set Point Note Def Ra...

Page 7: ...t of a faulty instrument either within the period of warranty or further to its expiry please contact our sales department to obtain authorisation for sending the instrument to our company The faulty...

Page 8: ...37 2005 CE EN13485 air S A 2 50 C 90 C with probe NTC 103AT11 7 5 INSTRUMENT ORDERING CODE Z31 instrument with mechanical keyboard Z31S instrument with Sensitive Touch keyboard a b c d e f g h ii jj...

Reviews: