0 ÷ 255

MODBUS Station
address (for serial
communication)

t.AS

31

oF

oF ÷ 999

Access Password to
parameter functions

t.PP

30

oF

oF/ 0.01 ÷ 9.59

(min.sec ) ÷  

30.0

(min.sec.x10)

Keyboard lock function
delay

t.Lo

29

oF

oF /  4

(1 / 2 / 3 =

don’t use)

Function mode key U
oF= No function
4= Switch on/Switch
off (Stand-by)

t.UF

28

t. - parameters relative to configuration of the keyboard

3

oF / 1 / 2 / 3 

Buzzer function mode
oF = disable
1 = active alarms only
2 = key pressed only
3 = active alarms and
key pressed

o.bu

27

o. -parameters relative to buzzer

1.00

oF/ 0.01 ÷ 9.59

(hrs.min. ) ÷

99.5

(hrs.min.x10)

Temperature Alarms
delay and unlock
display delay after
defrost 

A.dA

26

2.00

oF/ 0.01 ÷ 9.59

(hrs.min. ) ÷

99.5

(hrs.min.x10)

Temperature Alarms
delay at power on

A.PA

25

6 - PROBLEMS, MAINTENANCE AND GUARANTEE

6.1 - SIGNALLING

Replace the instrument
or ship to factory  for
repair

Fatal memory error 

Err

Press key P

Internal EEPROM
memory error

EPr

Check the correct
connection of the probe
with the instrument and
check the probe works
correctly

The probe may be
interrupted (E) or in
short circuit (-E), or may
measure a value outside
the range allowed

E1

-E1

Action 

Reason

Error

Other Signalling:

Minimum temperature alarm in progress

Lo

Maximum temperature alarm in progress

Hi

Post-defrosting in progress with  “d.dL”=Lb

PdF

Defrosting in progress with  “d.dL”=Lb

dEF

Keyboard lock

Ln

Delay at power-on in progress

od

Reason

Message

6.2 - CLEANING

We recommend  cleaning of the instrument only with a slightly wet
cloth using water and not abrasive cleaners or solvents.

6.3 - GUARANTEE AND REPAIRS

The instrument is under warranty against manufacturing flaws or
faulty material, that are found within 12 months from delivery date. 
The guarantee is limited to repairs or to the replacement of the
instrument. 
The eventual opening of the housing, the violation of the instrument
or the improper use and installation of the product will bring about
the immediate withdrawal of the warranty’s effects. 
In the event of a faulty instrument, either within the period of
warranty, or further to its expiry, please contact our sales
department to obtain  authorisation for sending the instrument to
our company. 
The faulty product must be shipped to ASCON TECNOLOGIC with
a detailed description of the faults found, without any fees or

charge for ASCON TECNOLOGIC, except in the event of
alternative agreements.

7 - TECHNICAL DATA

7.1 - ELECTRICAL DATA

Power supply: 12 VAC/VDC, 12...24 VAC/VDC, 100...240 VAC +/-
10%
Frequency AC: 50/60 Hz
Power consumption: 3 VA approx.
Input/s: 1 input for temperature probes: PTC (KTY 81-121, 990

 Ω

@ 25 °C) or  NTC (103AT-2, 10K

 @ 25 °C).

Output/s: 1 relay output SPST-NO or SPDT

12 A Res.,
30 LRA, 
5 FLA

10 (4) A

16 (9) A

Out - 16A - 1HP
250V, 1/2HP 125
VAC

UL 60730

EN 60730

EN 61810

12 A Max. for extractable terminal block model
Electrical life for relay outputs:   100000 op. (EN60730)
Action type:  type 1.B (EN 60730-1)
Overvoltage category:  II
Protection class :  Class II
Insulation:

   

Reinforced insulation between the low voltage part

(supply H type and relay output) and front panel; Reinforced
insulation between the low voltage section (supply H type and relay
output) and the extra low voltage section (inputs); Reinforced
between supply and relay output; No insulation between supply F
or G type and inputs.

7.2 - MECHANICAL DATA

Housing: Self-extinguishing plastic, UL 94 V0
Heat and fire resistance category :  D
Ball  Pressure Test secondo EN60730: acessible parts 75 °C;  
support live parts 125 °C
Dimensions: 78 x 35 mm, depth 64 mm
Weight: 120 g approx.
Mounting: Incorporated Flush in panel  (thickness max. 12 mm) in
71 x 29  mm hole
Connections:  2,5 mm

2

 screw terminals block or 2,5 mm

2

extractable screw terminals block for 0,2...2,5 mm

/ AWG 24...14

cables.
Degree of front panel protection : IP 65 (NEMA 3S) mounted in
panel with gasket
Pollution situation: 2
Operating temperature:  0 T 50 °C
Operating humidity: < 95 RH% without condensation
Storage temperature: -25 T +60 °C

7.3 - MECHANICAL DIMENSIONS, PANEL CUT-OUT AND
MOUNTING [mm]

35

78

35

78

ASCON TECNOLOGIC - Z31- 

 

-OPERATING INSTRUCTIONS- Vr. 02 - 03/12 -  ISTR-MZ31-ENG02 -  PAG. 7

Advanced Thermoelectric       toll-free 1-866-665-5434      (603) 888-2467      [email protected]

Summary of Contents for Z31

Page 1: ...TALLATION AND USE 3 KEYBOARD LOCK FUNCTION 2 6 RESET PARAMETERS TO DEFAULT VALUE LEVEL 2 5 CUSTOMIZED MODE PARAMETER PROGRAMMING PARAMETERS PROGRAMMING LEVEL 2 4 PARAMETER PROTECTION USING THE PASSWOR...

Page 2: ...identifies the first parameter Using the UP and DOWN keys the desired parameter can be selected and pressing the P key the display will alternately show the parameter code and its setting that can be...

Page 3: ...nting Make a hole 71 x 29 mm and insert the instrument fixing it with the provided special brackets We recommend that the gasket is mounted in order to obtain the front protection degree as declared A...

Page 4: ...r HC H SP off O N r HC H tim e r d SP Temp r d tim e r HC C O N O N ON ON O N off off off Temp Out Out In the event of probe error it is possible to set the instrument so that that the output continue...

Page 5: ...arm thresholds set in parameters A HA maximum alarm and A LA minimum alarm and the relative differential A Ad Through the parameter A Ay it is possible to set the alarm thresholds A HA and A LA which...

Page 6: ...nt Probes Type i SE 4 i parameters relative to inputs 0 0 LS HS Set Point SP 3 99 9 LS 999 Maximum Set Point S HS 2 50 0 99 9 HS Minimum Set Point S LS 1 S parameters relative to Set Point Note Def Ra...

Page 7: ...t of a faulty instrument either within the period of warranty or further to its expiry please contact our sales department to obtain authorisation for sending the instrument to our company The faulty...

Page 8: ...37 2005 CE EN13485 air S A 2 50 C 90 C with probe NTC 103AT11 7 5 INSTRUMENT ORDERING CODE Z31 instrument with mechanical keyboard Z31S instrument with Sensitive Touch keyboard a b c d e f g h ii jj...

Reviews: